dc.creator | Rodrigues M.A. | |
dc.creator | Luthi L.F. | |
dc.creator | Henriques G.E.P. | |
dc.date | 2012 | |
dc.date | 2015-06-26T20:29:42Z | |
dc.date | 2015-11-26T14:26:16Z | |
dc.date | 2015-06-26T20:29:42Z | |
dc.date | 2015-11-26T14:26:16Z | |
dc.date.accessioned | 2018-03-28T21:29:17Z | |
dc.date.available | 2018-03-28T21:29:17Z | |
dc.identifier | | |
dc.identifier | General Dentistry. , v. 60, n. 2, p. 122 - 127, 2012. | |
dc.identifier | 3636771 | |
dc.identifier | | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84858398692&partnerID=40&md5=2dcf764f17e00d3f0f6bb6ad0439b9c0 | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/97128 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/97128 | |
dc.identifier | 2-s2.0-84858398692 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1246040 | |
dc.description | The aim of this study was to evaluate the precision of three different mold filling techniques in order to obtain a cast simulating a three-unit, implant-retained, fixed prosthesis. Thirty casts (n = 10) were obtained using three different mold filling techniques. Group 1 used a unique fulfillment technique, Group 2 used a two-step fulfillment technique, and Group 3 used a latex cylinder technique. Using a metallic matrix, a titanium substructure was created to simulate a three-unit fixed prosthesis used as reference to evaluate the marginal misfit and tension forces in each cast. The vertical misfit was measured by an optical microscope with an increase of 120X and by an analysis unit using the one-screw test. The tension was quantified using strain gauges. The strain results showed a statistical difference between Group 3 and the other groups. The Tukey test showed no difference between the different treatment groups (p = 0.05). All three techniques were deemed efficient; however, considering that the cylinder latex technique induced less force toward the implants, it is the preferable technique for daily clinical practice. | |
dc.description | 60 | |
dc.description | 2 | |
dc.description | 122 | |
dc.description | 127 | |
dc.description | Jemt, T., Lekholm, U., Measurements of bone and frame-work deformations induced by misfit of implant superstructures: A pilot study in rabbits (1998) Clinical Oral Implants Research, 9 (4), pp. 272-280 | |
dc.description | Lindhe, J., Karring, T., Lang, N.P., (2008) Tratado de Periodontia Clinica e Implantologia Oral, , ed 5 Rio de Janeiro: Guanabara Koogan | |
dc.description | Somanathan, R.V., Simunek, A., Bukac, J., Brazda, T., Kopecka, D., Soft tissue esthetics in implant dentistry (2007) Acta Medica (Hradec Kralove), 50 (3), pp. 183-186 | |
dc.description | Skalak, R., Biomechanical considerations in osseointegrated prostheses (1983) J Prosthet Dent, 49 (6), pp. 843-848 | |
dc.description | Vigolo, P., Majzoub, Z., Cordioli, G., Evaluation of the accuracy of three techniques used for multiple implant abutment impressions (2003) Journal of Prosthetic Dentistry, 89 (2), pp. 186-192. , DOI 10.1067/mpr.2003.15 | |
dc.description | Zarb, G.A., Schmitt, A., Osseointegration and the edentulous predicament. The 10-year-old Toronto study (1991) Br Dent J, 170 (12), pp. 439-444 | |
dc.description | Naert, I., Quirynen, M., Van Steenberghe, D., Darius, P., A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects (1992) J Prosthet Dent, 68 (6), pp. 949-956 | |
dc.description | Adell, R., Lekholm, U., Rockler, B., Branemark, P.I., A 15-year study of osseointegrated implants in the treatment of the edentulous jaw (1981) International Journal of Oral Surgery, 10 (6), pp. 387-416 | |
dc.description | Bauman, G.R., Mills, M., Rapley, J.W., Hallmon, W.W., Plaque-induced inflammation around implants (1992) Int J Oral Maxillofac Implants, 7 (3), pp. 330-337 | |
dc.description | Carlson, B., Carlsson, G.E., Prosthodontic complications in osseointegrated dental implant treatment (1994) Int J Oral Maxillofac Implants, 9 (1), pp. 90-94 | |
dc.description | Kim, S., Nicholls, J.I., Han, C.-H., Lee, K.-W., Displacement of implant components from impressions to definitive casts (2006) International Journal of Oral and Maxillofacial Implants, 21 (5), pp. 747-755 | |
dc.description | Ceyhan, J.A., Johnson, G.H., Lepe, X., The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions (2003) Journal of Prosthetic Dentistry, 90 (2), pp. 143-149. , DOI 10.1016/S0022-3913(03)00276-2 | |
dc.description | Vigolo, P., Fonzi, F., Majzoub, Z., Cordioli, G., An evaluation of impression techniques for multiple internal connection implant prostheses (2004) Journal of Prosthetic Dentistry, 92 (5), pp. 470-476. , DOI 10.1016/j.prosdent.2004.08.015, PII S0022391304005323 | |
dc.description | Wee, A.G., Cheng, A.C., Eskridge, R.N., Accuracy of 3 conceptually different die systems used for implant casts (2002) Journal of Prosthetic Dentistry, 87 (1), pp. 23-29. , DOI 10.1067/mpr.2002.121110 | |
dc.description | Fenton, A.H., Assif, D., Zarb, G.A., Schmitt, A., The accuracy of implant impression procedures [abstract 1065] (1991) J Dent Res (2), 70, p. 399 | |
dc.description | Ivanhoe, J.R., Adrian, E.D., Krantz, W.A., Edge, M.J., An impression technique for osseointegrated implants (1991) J Prosthet Dent, 66 (3), pp. 410-411 | |
dc.description | Rodney, J., Johansen, R., Harris, W., Dimensional accuracy of two implant impression copings [abstract 953] (1991) J Dent Res, 70, p. 385 | |
dc.description | Phillips, K.M., Nicholls, I.J., Ma, T., Rubenstein, J., The accuracy of three implant impression techniques: A three-dimensional analysis (1994) Int J Oral Maxillofac Implant, 9, pp. 533-540 | |
dc.description | Hung, S.H., Purk, J.H., Tira, D.E., Eick, J.D., Accuracy of one step versus two-step putty wash addition silicone impression technique (1992) J Prosthet Dent, 67 (5), pp. 583-589 | |
dc.description | Carr, A.B., Comparison of impression techniques for a two-implant 15-degree divergent model (1992) Int J Oral Maxillofac Implants, 7 (4), pp. 468-475 | |
dc.description | Assif, D., Fenton, A., Zarb, G., Schmitt, A., Comparative accuracy of implant impression procedures (1992) Int J Perio Restor Dent, 12 (2), pp. 112-121 | |
dc.description | Burawi, G., Houston, F., Byrne, D., Claffey, N., A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implants system (1997) J Prosthet Dent, 77 (1), pp. 68-75 | |
dc.description | Dumbrigue, H.B., Gurun, D.C., Javid, N.S., Prefabricated acrylic resin bars for splinting implant transfer copings (2000) J Prosthet Dent, 84 (1), pp. 108-110 | |
dc.description | Herbst, D., Nel, J.C., Driessen, C.H., Becker, P.J., Evaluation of impression accuracy for osseointegrated implant supported superstructures (2000) J Prosthet Dent, 83 (5), pp. 555-561 | |
dc.description | Del'Acqua, M.A., Arioli-Filho, J.N., Compagnoni, M.A., Mollo Fde Jr., A., Accuracy of impression and pouring techniques for an implant-supported prosthesis (2008) Int J Oral Maxillofac Implants, 23 (2), pp. 226-236 | |
dc.description | Naconecy, M.M., Teixeira, E.R., Shinkai, R.S.A., Frasca, L.C.F., Cervieri, A., Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments (2004) International Journal of Oral and Maxillofacial Implants, 19 (2), pp. 192-198 | |
dc.description | Koke, U., Wolf, A., Lenz, P., Gilde, H., In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures (2004) Journal of Oral Rehabilitation, 31 (5), pp. 477-482. , DOI 10.1111/j.1365-2842.2004.01271.x | |
dc.description | Sartori, I.A.D.M., Ribeiro, R.F., Francischone, C.E., De Mattos, M.D.G.C., In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion (2004) Journal of Prosthetic Dentistry, 92 (2), pp. 132-138. , DOI 10.1016/j.prosdent.2004.04.001, PII S0022391304002033 | |
dc.description | Del'Acqua, M.A., (2005) Precisao das Tecnicas de Moldagem e Vazamento Para Proteses Implantossuportadas [Dissertacao]., , Araraquara: UNESP/ FOAR | |
dc.description | Jemt, T., Lie, A., Accuracy of implant-supported prostheses in edentulous jaw: Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique (1995) Clin Oral Implants Res, 6 (3), pp. 172-180 | |
dc.description | Castilho, A.A., Kojima, A.N., Pereira, S.M., De Vasconcellos, D.K., Itinoche, M.K., Faria, R., Bottino, M.A., In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments (2007) J Appl Oral Sci, 15 (3), pp. 241-246 | |
dc.description | Kan, J.Y., Clinical methods for evaluating implant framework fit (1999) J Prosthet Dent, 81 (1), pp. 7-13 | |
dc.description | McCartney, J.W., Pearson, R., Segmental framework matrix: Master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses (1994) J Prosthet Dent, 71 (2), pp. 197-200 | |
dc.description | Shiau, J.C., Chen, L.L., Wu, C.T., An accurate impression method for implant prosthesis fabrication (1994) J Prosthet Dent, 72 (1), pp. 23-25 | |
dc.language | en | |
dc.publisher | | |
dc.relation | General Dentistry | |
dc.rights | fechado | |
dc.source | Scopus | |
dc.title | The Influence Of Master Cast Technique On The Cast Precision Of Implant-retained Fixed Prostheses | |
dc.type | Artículos de revistas | |