dc.descriptionThe aim of this study was to evaluate the precision of three different mold filling techniques in order to obtain a cast simulating a three-unit, implant-retained, fixed prosthesis. Thirty casts (n = 10) were obtained using three different mold filling techniques. Group 1 used a unique fulfillment technique, Group 2 used a two-step fulfillment technique, and Group 3 used a latex cylinder technique. Using a metallic matrix, a titanium substructure was created to simulate a three-unit fixed prosthesis used as reference to evaluate the marginal misfit and tension forces in each cast. The vertical misfit was measured by an optical microscope with an increase of 120X and by an analysis unit using the one-screw test. The tension was quantified using strain gauges. The strain results showed a statistical difference between Group 3 and the other groups. The Tukey test showed no difference between the different treatment groups (p = 0.05). All three techniques were deemed efficient; however, considering that the cylinder latex technique induced less force toward the implants, it is the preferable technique for daily clinical practice.
dc.description60
dc.description2
dc.description122
dc.description127
dc.descriptionJemt, T., Lekholm, U., Measurements of bone and frame-work deformations induced by misfit of implant superstructures: A pilot study in rabbits (1998) Clinical Oral Implants Research, 9 (4), pp. 272-280
dc.descriptionLindhe, J., Karring, T., Lang, N.P., (2008) Tratado de Periodontia Clinica e Implantologia Oral, , ed 5 Rio de Janeiro: Guanabara Koogan
dc.descriptionSomanathan, R.V., Simunek, A., Bukac, J., Brazda, T., Kopecka, D., Soft tissue esthetics in implant dentistry (2007) Acta Medica (Hradec Kralove), 50 (3), pp. 183-186
dc.descriptionSkalak, R., Biomechanical considerations in osseointegrated prostheses (1983) J Prosthet Dent, 49 (6), pp. 843-848
dc.descriptionVigolo, P., Majzoub, Z., Cordioli, G., Evaluation of the accuracy of three techniques used for multiple implant abutment impressions (2003) Journal of Prosthetic Dentistry, 89 (2), pp. 186-192. , DOI 10.1067/mpr.2003.15
dc.descriptionZarb, G.A., Schmitt, A., Osseointegration and the edentulous predicament. The 10-year-old Toronto study (1991) Br Dent J, 170 (12), pp. 439-444
dc.descriptionNaert, I., Quirynen, M., Van Steenberghe, D., Darius, P., A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects (1992) J Prosthet Dent, 68 (6), pp. 949-956
dc.descriptionAdell, R., Lekholm, U., Rockler, B., Branemark, P.I., A 15-year study of osseointegrated implants in the treatment of the edentulous jaw (1981) International Journal of Oral Surgery, 10 (6), pp. 387-416
dc.descriptionBauman, G.R., Mills, M., Rapley, J.W., Hallmon, W.W., Plaque-induced inflammation around implants (1992) Int J Oral Maxillofac Implants, 7 (3), pp. 330-337
dc.descriptionCarlson, B., Carlsson, G.E., Prosthodontic complications in osseointegrated dental implant treatment (1994) Int J Oral Maxillofac Implants, 9 (1), pp. 90-94
dc.descriptionKim, S., Nicholls, J.I., Han, C.-H., Lee, K.-W., Displacement of implant components from impressions to definitive casts (2006) International Journal of Oral and Maxillofacial Implants, 21 (5), pp. 747-755
dc.descriptionCeyhan, J.A., Johnson, G.H., Lepe, X., The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions (2003) Journal of Prosthetic Dentistry, 90 (2), pp. 143-149. , DOI 10.1016/S0022-3913(03)00276-2
dc.descriptionVigolo, P., Fonzi, F., Majzoub, Z., Cordioli, G., An evaluation of impression techniques for multiple internal connection implant prostheses (2004) Journal of Prosthetic Dentistry, 92 (5), pp. 470-476. , DOI 10.1016/j.prosdent.2004.08.015, PII S0022391304005323
dc.descriptionWee, A.G., Cheng, A.C., Eskridge, R.N., Accuracy of 3 conceptually different die systems used for implant casts (2002) Journal of Prosthetic Dentistry, 87 (1), pp. 23-29. , DOI 10.1067/mpr.2002.121110
dc.descriptionFenton, A.H., Assif, D., Zarb, G.A., Schmitt, A., The accuracy of implant impression procedures [abstract 1065] (1991) J Dent Res (2), 70, p. 399
dc.descriptionIvanhoe, J.R., Adrian, E.D., Krantz, W.A., Edge, M.J., An impression technique for osseointegrated implants (1991) J Prosthet Dent, 66 (3), pp. 410-411
dc.descriptionRodney, J., Johansen, R., Harris, W., Dimensional accuracy of two implant impression copings [abstract 953] (1991) J Dent Res, 70, p. 385
dc.descriptionPhillips, K.M., Nicholls, I.J., Ma, T., Rubenstein, J., The accuracy of three implant impression techniques: A three-dimensional analysis (1994) Int J Oral Maxillofac Implant, 9, pp. 533-540
dc.descriptionHung, S.H., Purk, J.H., Tira, D.E., Eick, J.D., Accuracy of one step versus two-step putty wash addition silicone impression technique (1992) J Prosthet Dent, 67 (5), pp. 583-589
dc.descriptionCarr, A.B., Comparison of impression techniques for a two-implant 15-degree divergent model (1992) Int J Oral Maxillofac Implants, 7 (4), pp. 468-475
dc.descriptionAssif, D., Fenton, A., Zarb, G., Schmitt, A., Comparative accuracy of implant impression procedures (1992) Int J Perio Restor Dent, 12 (2), pp. 112-121
dc.descriptionBurawi, G., Houston, F., Byrne, D., Claffey, N., A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implants system (1997) J Prosthet Dent, 77 (1), pp. 68-75
dc.descriptionDumbrigue, H.B., Gurun, D.C., Javid, N.S., Prefabricated acrylic resin bars for splinting implant transfer copings (2000) J Prosthet Dent, 84 (1), pp. 108-110
dc.descriptionHerbst, D., Nel, J.C., Driessen, C.H., Becker, P.J., Evaluation of impression accuracy for osseointegrated implant supported superstructures (2000) J Prosthet Dent, 83 (5), pp. 555-561
dc.descriptionDel'Acqua, M.A., Arioli-Filho, J.N., Compagnoni, M.A., Mollo Fde Jr., A., Accuracy of impression and pouring techniques for an implant-supported prosthesis (2008) Int J Oral Maxillofac Implants, 23 (2), pp. 226-236
dc.descriptionNaconecy, M.M., Teixeira, E.R., Shinkai, R.S.A., Frasca, L.C.F., Cervieri, A., Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments (2004) International Journal of Oral and Maxillofacial Implants, 19 (2), pp. 192-198
dc.descriptionKoke, U., Wolf, A., Lenz, P., Gilde, H., In vitro investigation of marginal accuracy of implant-supported screw-retained partial dentures (2004) Journal of Oral Rehabilitation, 31 (5), pp. 477-482. , DOI 10.1111/j.1365-2842.2004.01271.x
dc.descriptionSartori, I.A.D.M., Ribeiro, R.F., Francischone, C.E., De Mattos, M.D.G.C., In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion (2004) Journal of Prosthetic Dentistry, 92 (2), pp. 132-138. , DOI 10.1016/j.prosdent.2004.04.001, PII S0022391304002033
dc.descriptionDel'Acqua, M.A., (2005) Precisao das Tecnicas de Moldagem e Vazamento Para Proteses Implantossuportadas [Dissertacao]., , Araraquara: UNESP/ FOAR
dc.descriptionJemt, T., Lie, A., Accuracy of implant-supported prostheses in edentulous jaw: Analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique (1995) Clin Oral Implants Res, 6 (3), pp. 172-180
dc.descriptionCastilho, A.A., Kojima, A.N., Pereira, S.M., De Vasconcellos, D.K., Itinoche, M.K., Faria, R., Bottino, M.A., In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments (2007) J Appl Oral Sci, 15 (3), pp. 241-246
dc.descriptionKan, J.Y., Clinical methods for evaluating implant framework fit (1999) J Prosthet Dent, 81 (1), pp. 7-13
dc.descriptionMcCartney, J.W., Pearson, R., Segmental framework matrix: Master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses (1994) J Prosthet Dent, 71 (2), pp. 197-200
dc.descriptionShiau, J.C., Chen, L.L., Wu, C.T., An accurate impression method for implant prosthesis fabrication (1994) J Prosthet Dent, 72 (1), pp. 23-25
dc.languageen
dc.publisher
dc.relationGeneral Dentistry
dc.rightsfechado
dc.sourceScopus
dc.titleThe Influence Of Master Cast Technique On The Cast Precision Of Implant-retained Fixed Prostheses
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución