dc.creatorOliveira M.L.
dc.creatorVieira M.L.
dc.creatorCruz A.D.
dc.creatorBoscolo F.N.
dc.creatorDe Almeida S.M.
dc.date2012
dc.date2015-06-26T20:29:11Z
dc.date2015-11-26T14:25:36Z
dc.date2015-06-26T20:29:11Z
dc.date2015-11-26T14:25:36Z
dc.date.accessioned2018-03-28T21:28:12Z
dc.date.available2018-03-28T21:28:12Z
dc.identifier
dc.identifierBrazilian Dental Journal. , v. 23, n. 6, p. 703 - 706, 2012.
dc.identifier1036440
dc.identifier10.1590/S0103-64402012000600013
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84872966565&partnerID=40&md5=7b4d4b02cef73266eaf1b07c25afe35b
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/96918
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/96918
dc.identifier2-s2.0-84872966565
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1245786
dc.descriptionThe aim of this study was to assess the applicability of gray scale inversion in performing digital linear endodontic measurements. Standardized digital images were taken of 40 extracted human permanent single-rooted teeth with K-files size 15 placed at different lengths in the root canal, using the CDR Wireless® digital system. All images were treated with Positive, a digital tool that inverts the grayscale value. Eight radiologists measured the distance between the lower limit of the rubber stop and the tip of the file on both original and positive images. After 15 days, they repeated this procedure in 50% of the image samples. The intra- and inter-examiner agreement was analyzed by intraclass correlation test, and the comparison between the two image groups and the actual lengths by the Student's t-test (α=0.05). Intra- and inter-examiner evaluation showed high reproducibility (r>0.95) of both original and positive images. No statistically significant differences (p>0.05) were found between measurements performed on original and positive images, but both differed significantly from the actual lengths (p<0.05). Gray scale inversion has low applicability in measuring endodontic files, since it did not improve the accuracy of measurements.
dc.description23
dc.description6
dc.description703
dc.description706
dc.descriptionWenzel, A., A review of dentists' use of digital radiography and caries diagnosis with digital systems (2006) Dentomaxillofac Radiol, 35, pp. 307-314
dc.descriptionLudlow, J.B., Mol, A., (2009), pp. p78-99. , Oral radiology: principles and interpretation. White SC, Pharoah MJ (Editor). 6th ed. St. Louis, MO: MosbyWoolhiser, G.A., Brand, J.W., Hoen, M.M., Geist, J.R., Pikula, A.A., Pink, F.E., Accuracy of film-based, digital, and enhanced digital images for endodontic length determination (2005) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 99, pp. 499-504
dc.descriptionDing, J., Gutmann, J.L., Fan, B., Lu, Y., Chen, H., Investigation of apex locators and related morphological factors (2010) J Endod, 36, pp. 1399-1403
dc.descriptionSouza, R.A., Sousa, Y.T., de Figueiredo, J.A., Dantas, J.C., Colombo, S., Pécora, J.D., Influence of apical foramen lateral opening and file size on cemental canal instrumentation (2012) Braz Dent J, 23, pp. 122-126
dc.descriptionKal, B.I., Baksi, B.G., Dündar, N., Sen, B.H., Effect of various digital processing algorithms on the measurement accuracy of endodontic file length (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 103, pp. 280-284
dc.descriptionOliveira, M.L., Ambrosano, G.M., Almeida, S.M., Haiter-Neto, F., Tosoni, G.M., Efficacy of several digital radiographic imaging systems for laboratory determination of endodontic file length (2011) Int Endod J, 44, pp. 469-473
dc.descriptionFriedlander, L.T., Love, R.M., Chandler, N.P., A comparison of phosphor-plate digital images with conventional radiographs for the perceived clarity of fine endodontic files and periapical lesions (2002) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 93, pp. 21-27
dc.descriptionBrüllmann, D.D., Röhrig, B., Sulayman, S.L., Schulze, R., Length of endodontic files measured in digital radiographs with and without noise-suppression filters: An ex-vivo study (2011) Dentomaxillofac Radiol, 40, pp. 170-176
dc.descriptionKamburoǧlu, K., Murat, S., Pehlivan, S.Y., The effects of digital image enhancement on the detection of vertical root fracture (2010) Dent Traumatol, 26, pp. 47-51
dc.descriptionKamburoǧlu, K., Barenboim, S., Kaffe, I., Comparison of conventional film with different digital and digitally filtered images in the detection of simulated internal resorption cavities-an ex vivo study in human cadaver jaws (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 105, pp. 790-797
dc.descriptionPaludo, L., Souza, S.L., Só, M.V., Rosa, R.A., Vier-Pelisser, F.V., Duarte, M.A., An in vivo radiographic evaluation of the accuracy of Apex and iPex electronic Apex locators (2012) Braz Dent J, 23, pp. 54-58
dc.descriptionVasconcelos, B.C., Matos, L.A., Pinheiro-Júnior, E.C., Menezes, A.S., Vivacqua-Gomes, N., Ex vivo accuracy of three electronic apex locators using different apical file sizes (2012) Braz Dent J, 23, pp. 199-204
dc.descriptionde Oliveira, M.L., Pinto, G.C., Ambrosano, G.M., Tosoni, G.M., Effect of combined digital imaging parameters on endodontic file measurements (2012) J Endod, 38, pp. 1404-1407
dc.descriptionShanmugaraj, M., Nivedha, R., Mathan, R., Balagopal, S., Evaluation of working length determination methods: An in vivo/ex vivo study (2007) Indian J Dent Res, 18, pp. 60-62
dc.descriptionVelders, X.L., Sanderink, G.C., van der Stelt, P.F., Dose reduction of two digital sensor systems measuring file lengths (1996) Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 81, pp. 607-612
dc.descriptionWenzel, A., Kirkevang, L.L., Students' attitudes to digital radiography and measurement accuracy of two digital systems in connection with root canal treatment (2004) Eur J Dent Educ, 8, pp. 167-171
dc.languageen
dc.publisher
dc.relationBrazilian Dental Journal
dc.rightsaberto
dc.sourceScopus
dc.titleGray Scale Inversion In Digital Image For Measurement Of Tooth Length
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución