dc.creatorAssef A.A.
dc.creatorMaia J.M.
dc.creatorSchneider F.K.
dc.creatorCosta E.T.
dc.creatorDa Button V.L.S.N.
dc.date2012
dc.date2015-06-26T20:29:04Z
dc.date2015-11-26T14:25:19Z
dc.date2015-06-26T20:29:04Z
dc.date2015-11-26T14:25:19Z
dc.date.accessioned2018-03-28T21:27:44Z
dc.date.available2018-03-28T21:27:44Z
dc.identifier
dc.identifierControle Y Automacao. , v. 23, n. 6, p. 667 - 678, 2012.
dc.identifier1031759
dc.identifier10.1590/S0103-17592012000600002
dc.identifierhttp://www.scopus.com/inward/record.url?eid=2-s2.0-84873299592&partnerID=40&md5=be32c4c5054494b47722ff8ea7f72c1d
dc.identifierhttp://www.repositorio.unicamp.br/handle/REPOSIP/96875
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/96875
dc.identifier2-s2.0-84873299592
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1245672
dc.descriptionThis paper presents the development of a digital beamformer transmitter system for generation of arbitrary ultrasound waveforms, specifically designed for research purposes. The proposed architecture has 8 independent excitation channels and uses an FPGA device (Field Programmable Gated Array) for electronic control channel generation of ultrasonic acoustic beam transmission. The system allows operation in pulse-echo mode, with pulse repetition rate of excitation between 62.5 Hz and 8 kHz, or single pulse, center frequency between 500 kHz and 20 MHz, excitation voltage between -100 and +100 V, and individual control of amplitude apodization, phase angle and time delay trigger. The mathematical method for determining the digital signals of excitation is presented and validated through practical results for waveform generation with Gaussian profile and center frequency of 20 MHz, in a load formed by a 220 pF capacitor in parallel with a resistor of 1 kΩ. The results show that the proposed flexible and fully programmable architecture, can support the development of new algorithms and sophisticated processing techniques of the transmission beamformer.
dc.description23
dc.description6
dc.description667
dc.description678
dc.description(2010) Cyclone III Device Handbook I-II. Altera Handbook, , Altera Corporation, San Jose, CA USA
dc.description(2007) High Speed Converter Evaluation Platform - HSC-ADC-EVALC, , Analog Devices Inc., Data sheet, Norwood, MA, USA
dc.descriptionAssef, A.A., Maia, J.M., Armstrong, R.B., Ashihara, H.M., Costa, E.T., Da Button, V.L.S.N., Sistema digital gerador de forma de onda arbitrária para aplicações de ultrassom (2010) XXII Congresso Brasileiro de Engenharia Biomédica (CBEB) - 2010, pp. 391-394. , Tiradentes MG Brasil
dc.descriptionAssef, A.A., Maia, J.M., Gewehr, P.M., Gamba, H.R., Costa, E.T., Button, V.L.S.N., Sistema para geração, aquisição e processamento de sinais de ultrasom (2009) Sba Controle & Automação, 20 (2), pp. 145-155
dc.descriptionBasoglu, C., Managuli, R., York, G., Kim, Y., Computing requirements of modern medical diagnostic ultrasound machines (1998) Parallel Computing, 24 (9-10), pp. 1407-1431. , PII S0167819198000647
dc.descriptionBassi, L., Boni, E., Cellai, A., Dallai, A., Guidi, F., Ricci, S., Tortoli, P., A Novel Digital Ultrasound System for Experimental Research Activities. 11th Euromicro Conference on Digital System Design Architectures (2008) Methods and Tools, pp. 413-417
dc.descriptionBrown, J.A., Lockwood, G.R., A low-cost, high-performance pulse generator for ultrasound imaging (2002) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 49 (6), pp. 848-851. , DOI 10.1109/TUFFC.2002.1009345
dc.descriptionBrunner, E., (2002) Ultrasound System Considerations and Their Impact on Front-end Components., , Application Note, Analog Devices, Norwood, MA, USA
dc.descriptionHuang, S.W., Li, P.C., Arbitrary waveform coded excitation using bipolar square wave pulsers in medical ultrasound (2006) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 53 (1), pp. 106-116
dc.descriptionHu, C.H., Zhou, Q., Shung, K.K., Design and implementation of high frequency ultrasound pulsed- wave doppler using FPGA (2008) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 55 (9), pp. 2109-2111
dc.descriptionJensen, J.A., Holm, O., Jensen, L.J., Bendsen, H., Nikolov, S.I., Tomov, B.G., Munk, P., Gammelmark, K.L., Ultrasound research scanner for real-time synthetic aperture data acquisition (2005) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 52 (5), pp. 881-889
dc.descriptionKim, Y., Kim, J.H., Basoglu, C., Winter, T.C., Programmable ultrasound imaging using multimedia technologies: A next-generation ultrasound machine (1997) IEEE Transactions on Information Technology in Biomedicine, 1 (1), pp. 19-29. , PII S1089777197035589
dc.descriptionMahdy, E.R., Khalil, R.M., Sherif, S., Kadah, Y.M.K., FPGA based backend system for medical bmode ultrasound imaging (2006) Proc. Cairo International Biomedical Engineering Conference
dc.description(2011) Medical Imaging: Ultrasound Imaging Systems, , Maxim Integrated Products, Application Note, Sunnyvale, CA, USA
dc.descriptionMisaridis, T., Jensen, J.A., Use of modulated excitation signals in ultrasound. Part I: Basic concepts and expected benefits (2005) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 50, pp. 192-207
dc.description(2007) Introduction to Phased Array Ultrasonic Technology Applications: R/D Tech Guideline, , Olympus NDT, Olympus NDT, MA, USA
dc.descriptionPark, J.H., Yoon, C., Chang, J.H., Yoo, Y., Song, T.K., A real-time synthetic aperture beamformer formedical ultrasound imaging (2010) IEEE Ultrasonics Symposium (IUS), pp. 1992-1995
dc.descriptionRicci, S., Bassi, L., Boni, E., Dallai, A., Tortoli, P., Multichannel FPGA-based arbitrary waveform generator for medical ultrasound (2007) Electronics Letters, 43 (24), pp. 1335-1336. , DOI 10.1049/el:20072859
dc.descriptionSchneider, F.K., Agarwal, A., Mo Yoo, Y., Fukuoka, T., Kim, Y., A fully programmable computing architecture for medical ultrasound machines (2010) IEEE Transactions on Information Technology in Biomedicine, 14, pp. 538-540
dc.descriptionSilkdar, S., Managuli, R., Gong, L., A single mediaprocessor-based programmable ultrasound system (2003) IEEE Transactions on Information Technology in Biomedicine, 7, pp. 64-70
dc.description(2009) MD2130 - High Speed Ultrasound Beamforming Source Driver, , Supertex Inc., Data sheet, Sunnyvale, CA, USA
dc.description(2008) AFE5805 - Fully- Integrated, 8-channel Analog Front-end for Ultrasound, , Texas Instruments Inc., Data sheet, Dallas, Texas, USA
dc.descriptionTomov, B.G., Jensen, J.A., Compact FPGA-based beamformer using oversampled 1-bit A/D converters (2005) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 52 (5), pp. 870-880. , DOI 10.1109/TUFFC.2005.1503973
dc.descriptionXu, X., Yen, J.T., Shung, K.K., A low-cost bipolar pulse generator for high-frequency ultrasound applications (2007) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 54 (2), pp. 443-447. , DOI 10.1109/TUFFC.2007.259
dc.descriptionZhou, S., Hossack, J.A., Dynamic-transmit focusing using time dependent focal zone and center frequency (2003) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 50, pp. 142-152
dc.languagept
dc.publisher
dc.relationControle y Automacao
dc.rightsaberto
dc.sourceScopus
dc.titleMultichannel Arbitrary Waveform Beamformer Transmitter For Experimental Research Activities Of Ultrasound [beamformer De Transmissão Multicanal De Forma De Onda Arbitrária Para Atividades De Pesquisa Experimental Do Ultrassom]
dc.typeArtículos de revistas