Artículos de revistas
Full Threshold Vs. (sita) In Glaucomatous Patients Undergoing Automated Perimetry For The First Time [full Threshold Vs. Swedish Interactive Threshold Algorithm (sita) Em Pacientes Glaucomatosos Submetidos à Perimetria Computadorizada Pela Primeira Vez]
Registro en:
Arquivos Brasileiros De Oftalmologia. , v. 69, n. 2, p. 145 - 150, 2006.
42749
2-s2.0-33646756493
Autor
Schimiti R.B.
Arciery E.S.
Avelino R.R.
Matsuo T.
Costa V.P.
Institución
Resumen
Purpose: To compare the Full Threshold (FF) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. Methods: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. Results: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1 % for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). Conclusion: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations. 69 2 145 150 Anderson, D.R., Patella, V.M., (1999) Automated Static Perimetry, , 2a ed. St Louis: Mosby Year Book Costa, V.P., (2000) Perimetria Computadorizada: Um Guia Básico De Interpretação, , 2a ed. São Paulo: RioMed Shirato, S., Inoue, R., Fukushima, K., Suzuki, Y., Clinical evaluation of SITA: A new family of parimetric testing strategies (1999) Graefes Arch Clin Exp Ophthalmol, 237 (1), pp. 29-34 Bengtsson, B., Heijl, A., Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma (1998) Acta Ophthalmol Scand, 76 (3), pp. 268-272 Artes, P.H., Iwase, A., Ohno, Y., Kitazawa, Y., Chauhan, B.C., Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast Strategies (2002) Invest Ophthalmol Vis Sci, 43 (8), pp. 2654-2659 Sharma, A.K., Goldberg, I., Graham, S.L., Mohsin, M., Comparison of the Humphrey swedish interactive thresholding algorithm (SITA) and full threshold strategies (2000) J Glaucoma, 9 (1), pp. 20-27 Schimiti, R.B., Costa, V.P., Perimetria computadorizada Humphrey (2003) Semiologia Ocular, pp. 289-300. , Yamane R. 2a ed. Rio de Janeiro: Cultura Médica Wild, J.M., Pacey, I.E., Hancock, S.A., Cunliffe, I.A., Between-algorithm, between-individual differences in normal perimetric sensitivity: Full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm (1999) Invest Ophthalmol Vis Sci, 40 (6), pp. 1152-1161 Sekhar, G.C., Naduvilath, T.J., Lakkai, M., Jayakumar, A.J., Pandi, G.T., Mandal, A.K., Honavar, S.G., Sensitivity of Swedish interactive threshold algorithm compared with standard full threshold algorithm in Humphrey visual field testing (2000) Ophthalmology, 107 (7), pp. 1303-1308 Budenz, D.L., Rhee, P., Feuer, W.J., McSoley, J., Johnson, C.A., Anderson, D.R., Sensitivity and specificity of the Swedish interactive threshold algorithm for glaucomatous visual field defects (2002) Ophthalmology, 109 (6), pp. 1052-1058 Cbylack Jr., L.T., Wolfe, J.K., Singer, D.M., Leske, M.C., Bullimore, M.A., Bailey, I.L., The Lens Opacities Classification System III (1993) Arch Ophthalmol, 111 (6), pp. 831-836. , The Longitudinal Study of Cataract Study Group Budenz, D.L., Rhee, P., Feuer, W.J., McSoley, J., Johnson, C.A., Anderson, D.R., Comparison of glaucomatous visual field defects using standard full threshold and Swedish interactive threshold algorithms (2002) Arch Ophthalmol, 120 (9), pp. 1136-1141 Wild, J.M., Pacey, I.E., O'Neill, E.C., Cunliffe, I.A., The SITA perimetric threshold algorithm in glaucoma (1999) Invest Ophthalmol Vis Sci, 40 (9), pp. 1998-2009 Bengtsson, B., Heijl, A., Inter-subject variability and normal limits of the SITA Standard, SITA Fast, and the Humphrey Full Threshold computerized perimetry strategies, SITA STATPAC (1999) Acta Ophthalmol Scand, 77 (2), pp. 125-129 Yenice, O., Temel, A., Evaluation of two Humphrey perimetry programs: Full threshold and SITA standard testing strategy for learning effect (2005) Eur J Ophthalmol, 15 (2), pp. 209-212 Heijl, A., Bengtsson, B., The effect of perimetric experience in patients with glaucoma (1996) Arch Ophthalmol, 14 (1), pp. 19-22 Schimiti, R.B., Avelino, R.R., Kara-José, N., Costa, V.P., Full-threshold versus Swedish Interactive Threshold Algorithm (SITA) in normal individuals undergoing automated perimetry for the first time (2002) Ophthalmology, 109 (11), pp. 2084-2092. , discussion 2092 Bengtsson, B., Heijl, A., Comparing significance and magnitude of glaucomatous visual field defects using the SITA and Full Threshold strategies (1999) Acta Ophthalmol Scand, 77 (2), pp. 143-146 Garway-Heath, D.F., Hitchings, R.A., Sources of bias in studies of optic disc and retinal nerve fibre layer morphology (1998) Br J Ophthalmol, 82 (9), p. 986