dc.creator | Faverani L.P. | |
dc.creator | Barao V.A.R. | |
dc.creator | Ramalho-Ferreira G. | |
dc.creator | Ferreira M.B. | |
dc.creator | Garcia-Junior I.R. | |
dc.creator | Assuncao W.G. | |
dc.date | 2014 | |
dc.date | 2015-06-25T17:53:22Z | |
dc.date | 2015-11-26T14:23:15Z | |
dc.date | 2015-06-25T17:53:22Z | |
dc.date | 2015-11-26T14:23:15Z | |
dc.date.accessioned | 2018-03-28T21:25:12Z | |
dc.date.available | 2018-03-28T21:25:12Z | |
dc.identifier | | |
dc.identifier | Journal Of Biomedical Materials Research - Part B Applied Biomaterials. , v. 102, n. 1, p. 22 - 30, 2014. | |
dc.identifier | 15524973 | |
dc.identifier | 10.1002/jbm.b.32949 | |
dc.identifier | http://www.scopus.com/inward/record.url?eid=2-s2.0-84890309852&partnerID=40&md5=b834722b3b2168bf712fe5b202c5e88e | |
dc.identifier | http://www.repositorio.unicamp.br/handle/REPOSIP/86436 | |
dc.identifier | http://repositorio.unicamp.br/jspui/handle/REPOSIP/86436 | |
dc.identifier | 2-s2.0-84890309852 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1245052 | |
dc.description | The effects of carbamide peroxide, hydrogen peroxide and cola soft drink on the topographic modifications of commercially-pure titanium (CP-Ti) and Ti-6Al-4V were investigated. Ti discs were divided into 18 groups (n = 4) based on the solution treatment and Ti type. Specimens were immersed in 3 mL of each solution for 4 h per day (for the remaining 20 h, discs were left dry or immersed in artificial saliva) for 15 days. For control, specimens were immersed in only artificial saliva. Ti surfaces were examined using scanning electron (SEM) and atomic force (AFM) microscopes and their surface roughness (in μm) and surface chemical modifications were investigated. Data were analyzed by ANOVA and Tukey's test (α = 0.05). Groups immersed in 35% hydrogen peroxide showed the highest roughness (Ra) (171.65 ± 4.04 for CP-Ti and 145.91 ± 14.71 for Ti-6Al-4V) (p < 0.05), followed by groups treated with carbamide peroxide 16% (110.91 ± 0.8 for CP-Ti and 49.28 ± 0.36 for Ti-6Al-4V) and 35% (65.67 ± 1.6 for CP-Ti and 53.87 ± 1.98 for Ti-6Al-4V); treatment with artificial saliva did not affect the results. These values were statistically superior to those observed prior to the treatment and to those of the control group (31.0 ± 0.99 for CP-Ti and 29.95 ± 0.58 for Ti-6Al-4V). Cola soft drink did not alter the surface roughness of either Ti type (p > 0.05). SEM and AFM revealed dramatic changes in the specimens surfaces immersed in the 35% hydrogen peroxide, mainly for CP-Ti. No detectable chemical modifications on the Ti surface were observed. Bleaching agents promoted significant changes in Ti topography, which could affect the longevity of implants treatments. © 2013 Wiley Periodicals, Inc. | |
dc.description | 102 | |
dc.description | 1 | |
dc.description | 22 | |
dc.description | 30 | |
dc.description | Branemark, P.I., Hansson, B.O., Adell, R., Breine, U., Lindstrom, J., Hallen, O., Ohman, A., Osseointegrated implants in the treatment of the edentulous jaw: Experience from a 10-year period (1977) Scand J Plast Reconstr Surg Suppl, 16, pp. 1-132 | |
dc.description | Cortada, M., Giner, L., Costa, S., Gil, F.J., Rodriguez, D., Planell, J.A., Galvanic corrosion behavior of titanium implants coupled to dental alloys (2000) J Mater Sci Mater Med, 11, pp. 287-293 | |
dc.description | Schiff, N., Grosgogeat, B., Lissac, M., Dalard, F., Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys (2002) Biomaterials, 23, pp. 1995-2002 | |
dc.description | Mabboux, F., Ponsonnet, L., Morrier, J.J., Jaffrezic, N., Barsotti, O., Surface free energy and bacterial retention to saliva-coated dental implant materials - An in vitro study (2004) Colloids Surf B Biointerfaces, 39, pp. 199-205 | |
dc.description | Vieira, A.C., Ribeiro, A.R., Rocha, L.A., Celis, J.P., Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva (2006) Wear, 261, pp. 994-1001 | |
dc.description | Nikolopoulou, F., Saliva and dental implants (2006) Implant Dent, 15, pp. 372-376 | |
dc.description | Correa, C.B., Pires, J.R., Fernandes-Filho, R.B., Sartori, R., Vaz, L.G., Fatigue and fluoride corrosion on Streptococcus mutans adherence to titanium-based implant/component surfaces (2009) J Prosthodont, 18, pp. 382-387 | |
dc.description | Barao, V.A., Mathew, M.T., Assuncao, W.G., Yuan, J.C., Wimmer, M.A., Sukotjo, C., Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - An electrochemical study (2012) Clin Oral Implants Res, 23, pp. 1055-1062 | |
dc.description | Barao, V.A., Mathew, M.T., Assuncao, W.G., Yuan, J.C., Wimmer, M.A., Sukotjo, C., The role of lipopolysaccharide on the electrochemical behavior of titanium (2011) J Dent Res, 90, pp. 613-618 | |
dc.description | Lazzara, R.J., Testori, T., Trisi, P., Porter, S.S., Weinstein, R.L., A human histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces (1999) Int J Periodontics Restorative Dent, 19, pp. 117-129 | |
dc.description | Chaturvedi, T.P., An overview of the corrosion aspect of dental implants (titanium and its alloys) (2009) Indian J Dent Res, 20, pp. 91-98 | |
dc.description | Strietzel, R., Hosch, A., Kalbfleisch, H., Buch, D., In vitro corrosion of titanium (1998) Biomaterials, 19, pp. 1495-1499 | |
dc.description | Horwitz, J., Machtei, E.E., Zuabi, O., Peled, M., Amine fluoride/stannous fluoride and chlorhexidine mouthwashes as adjuncts to single-stage dental implants: A comparative study (2005) J Periodontol, 76, pp. 334-340 | |
dc.description | Zhou, Y.L., Niinomi, M., Akahori, T., Fukui, H., Toda, H., Corrosion resistance and biocompatibility of Ti-Ta alloys for biomedical applications (2005) Mater Sci Eng, 398, pp. 28-36 | |
dc.description | Oliveira, N.T., Guastaldi, A.C., Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications (2009) Acta Biomater, 5, pp. 399-405 | |
dc.description | Mareci, D., Chelariu, R., Gordin, D.M., Ungureanu, G., Gloriant, T., Comparative corrosion study of Ti-Ta alloys for dental applications (2009) Acta Biomater, 5, pp. 3625-3639 | |
dc.description | Mathew, M.T., Barao, V.A., Yuan, J.C., Assuncao, W.G., Sukotjo, C., Wimmer, M.A., What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? (2012) J Mech Behav Biomed Mater, 8, pp. 71-85 | |
dc.description | Kedici, S.P., Aksut, A.A., Kilicarslan, M.A., Bayramoglu, G., Gokdemir, K., Corrosion behaviour of dental metals and alloys in different media (1998) J Oral Rehabil, 25, pp. 800-808 | |
dc.description | Al-Salehi, S.K., Hatton, P.V., Miller, C.A., McLeod, C., Joiner, A., The effect of carbamide peroxide treatment on metal ion release from dental amalgam (2006) Dental Mater, 22, pp. 948-953 | |
dc.description | Duffey, K.J., Popkin, B.M., Adults with healthier dietary patterns have healthier beverage patterns (2006) J Nutr, 136, pp. 2901-2907 | |
dc.description | Herrel, L., Pattaras, J., Solomon, T., Ogan, K., Urinary stone risk and cola consumption (2012) Urology, 80, pp. 990-994 | |
dc.description | Abu-Eittah, M.R., Mandour, M.H., In vitro study of the effect of three hydrogen peroxide concentrations on the corrosion behavior and surface topography of alumina-reinforced dental ceramic (2011) J Prosthodont, 20, pp. 541-552 | |
dc.description | Turker, S.B., Biskin, T., The effect of bleaching agents on the microhardness of dental aesthetic restorative materials (2002) J Oral Rehabil, 29, pp. 657-661 | |
dc.description | Turker, S.B., Biskin, T., Effect of three bleaching agents on the surface properties of three different esthetic restorative materials (2003) J Prosthet Dent, 89, pp. 466-473 | |
dc.description | Villalta, P., Lu, H., Okte, Z., Garcia-Godoy, F., Powers, J.M., Effects of staining and bleaching on color change of dental composite resins (2006) J Prosthet Dent, 95, pp. 137-142 | |
dc.description | Abd Elhamid, M., Mosallam, R., Effect of bleaching versus repolishing on colour and surface topography of stained resin composite (2010) Aust Dent J, 55, pp. 390-398 | |
dc.description | Aguiar, F.H., Georgetto, M.H., Soares, G.P., Catelan, A., Dos Santos, P.H., Ambrosano, G.M., Figueroba, S.R., Lovadino, J.R., Effect of different light-curing modes on degree of conversion, staining susceptibility and stain's retention using different beverages in a nanofilled composite resin (2011) J Esthet Restor Dent, 23, pp. 106-114 | |
dc.description | Correr, G.M., Bruschi Alonso, R.C., Baratto-Filho, F., Correr-Sobrinho, L., Sinhoreti, M.A., Puppin-Rontani, R.M., In vitro long-term degradation of aesthetic restorative materials in food-simulating media (2012) Acta Odontol Scand, 70, pp. 101-108 | |
dc.description | Fujii, M., Kitasako, Y., Sadr, A., Tagami, J., Roughness and pH changes of enamel surface induced by soft drinks in vitro-applications of stylus profilometry, focus variation 3D scanning microscopy and micro pH sensor (2011) Dent Mater J, 30, pp. 404-410 | |
dc.description | Da Silva, M.A.B., Fardin, A.B., De Vasconcellos, R.C.C., Santos, L.D., Tonholo, J., Da Silva, J.G., Dos Reis, J.I.L., Analysis of roughness and surface hardness of a dental composite using atomic force microscopy and microhardness testing (2011) Microsc Microanal, 17, pp. 446-451 | |
dc.description | Yap, A.U., Lye, K.W., Sau, C.W., Surface characteristics of tooth-colored restoratives polished utilizing different polishing systems (1997) Oper Dent, 22, pp. 260-265 | |
dc.description | Yap, A.U., Tan, D.T., Goh, B.K., Kuah, H.G., Goh, M., Effect of food-simulating liquids on the flexural strength of composite and polyacid-modified composite restoratives (2000) Oper Dent, 25, pp. 202-208 | |
dc.description | Paravina, R.D., Roeder, L., Lu, H., Vogel, K., Powers, J.M., Effect of finishing and polishing procedures on surface roughness, gloss and color of resin-based composites (2004) Am J Dent, 17, pp. 262-266 | |
dc.description | Wongkhantee, S., Patanapiradej, V., Maneenut, C., Tantbirojn, D., Effect of acidic food and drinks on surface hardness of enamel, dentine, and tooth-coloured filling materials (2006) J Dent, 34, pp. 214-220 | |
dc.description | Kitchens, M., Owens, B.M., Effect of carbonated beverages, coffee, sports and high energy drinks, and bottled water on the in vitro erosion characteristics of dental enamel (2007) J Clin Pediatr Dent, 31, pp. 153-159 | |
dc.description | Parenti, S.I., Guicciardi, S., Melandri, C., Sprio, S., Lafratta, E., Tampieri, A., Bonetti, G.A., Effect of soft drinks on the physical and chemical features of nickel-titanium-based orthodontic wires (2012) Acta Odontol Scand, 70, pp. 49-55 | |
dc.description | Mjoberg, B., Hellquist, E., Mallmin, H., Lindh, U., Aluminum, Alzheimer's disease and bone fragility (1997) Acta Orthop Scand, 68, pp. 511-514 | |
dc.description | Karrholm, J., Frech, W., Nivbrant, B., Malchau, H., Snorrason, F., Herberts, P., Fixation and metal release from the Tifit femoral stem prosthesis: 5-year follow-up of 64 cases (1998) Acta Orthop Scand, 69, pp. 369-378 | |
dc.description | Jacobs, J.J., Gilbert, J.L., Urban, R.M., Corrosion of metal orthopaedic implants (1998) J Bone Joint Surg Am, 80, pp. 268-282 | |
dc.description | Truong, V.K., Lapovok, R., Estrin, Y.S., Rundell, S., Wang, J.Y., Fluke, C.J., Crawford, R.J., Ivanova, E.P., The influence of nano-scale surface roughness on bacterial adhesion to ultrafine-grained titanium (2010) Biomaterials, 31, pp. 3674-3683 | |
dc.description | Quirynen, M., Marechal, M., Busscher, H.J., Weerkamp, A.H., Darius, P.L., Van Steenberghe, D., The influence of surface free energy and surface roughness on early plaque formation. An in vivo study in man (1990) J Clin Periodontol, 17, pp. 138-144 | |
dc.description | Kim, M.L., Jeong, C.M., Jeon, Y.C., Byon, E., Jeong, Y., Cho, L.R., The effects of Mg-ion implantation and sandblasting on Porphyromonas gingivalis attachment (2012) Clin Oral Implants Res, 23, pp. 245-252 | |
dc.description | Elter, C., Heuer, W., Demling, A., Hannig, M., Heidenblut, T., Bach, F.W., Stiesch-Scholz, M., Supra- and subgingival biofilm formation on implant abutments with different surface characteristics (2008) Int J Oral Maxillofac Implants, 23, pp. 327-334 | |
dc.description | Van Steenberghe, D., Periodontal aspects of osseointegrated oral implants modum Branemark (1988) Dental Clin North Am, 32, pp. 355-370 | |
dc.description | Gould, T.R., Brunette, D.M., Westbury, L., The attachment mechanism of epithelial cells to titanium in vitro (1981) J Periodont Res, 16, pp. 611-616 | |
dc.description | Albrektsson, T., Buser, D., Sennerby, L., Crestal bone loss and oral implants (2012) Clin Implant Dent Relat Res, 14, pp. 783-791 | |
dc.description | Huang, H.H., Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy (2003) Biomaterials, 24, pp. 275-282 | |
dc.description | Souza, M.E., Lima, L., Lima, C.R., Zavaglia, C.A., Freire, C.M., Effects of pH on the electrochemical behaviour of titanium alloys for implant applications (2009) J Mater Sci Mater Med, 20, pp. 549-552 | |
dc.language | en | |
dc.publisher | | |
dc.relation | Journal of Biomedical Materials Research - Part B Applied Biomaterials | |
dc.rights | fechado | |
dc.source | Scopus | |
dc.title | Effect Of Bleaching Agents And Soft Drink On Titanium Surface Topography | |
dc.type | Artículos de revistas | |