Artículos de revistas
Characterization Of Anfo Explosive By High Accuracy Esi(±)-ftms With Forensic Identification On Real Samples By Easi(-)-ms
Registro en:
Forensic Science International. Elsevier Ireland Ltd, v. 249, n. , p. 156 - 164, 2015.
3790738
10.1016/j.forsciint.2015.01.006
2-s2.0-84922979006
Autor
Hernandes V.V.
Franco M.F.
Santos J.M.
Melendez-Perez J.J.
Morais D.R.
Rocha W.F.D.C.
Borges R.
de Souza W.
Zacca J.J.
Logrado L.P.L.
Eberlin M.N.
Correa D.N.
Institución
Resumen
Ammonium nitrate fuel oil (ANFO) is an explosive used in many civil applications. In Brazil, ANFO has unfortunately also been used in criminal attacks, mainly in automated teller machine (ATM) explosions. In this paper, we describe a detailed characterization of the ANFO composition and its two main constituents (diesel and a nitrate explosive) using high resolution and accuracy mass spectrometry performed on an FT-ICR-mass spectrometer with electrospray ionization (ESI(±)-FTMS) in both the positive and negative ion modes. Via ESI(-)-MS, an ion marker for ANFO was characterized. Using a direct and simple ambient desorption/ionization technique, i.e., easy ambient sonic-spray ionization mass spectrometry (EASI-MS), in a simpler, lower accuracy but robust single quadrupole mass spectrometer, the ANFO ion marker was directly detected from the surface of banknotes collected from ATM explosion theft. 249
156 164 Beveridge, A., (1998) Forensic Investigation of Explosions, , Taylor & Francis Marshall, M., Oxley, J.C., (2009) Aspects of Explosives Detection, , Elsevier Contraf-Cut, C.N.V.T., (2013) Sixth National Survey on Attacks on Banks in Brazil, , http://www.bancariosdf.com.br/site/images/stories/pdf/14321113430.pdf, Available from Walters, A.N., Slurry and emulsion explosives: new tools for terrorists, new challenges for detection and identification (1993) Advances in Analysis and Detection of Explosives, , CRM.Springer, Netherlands, J. Yinons (Ed.) Coldwell, B.B., The application of ultra-violet light and diphenylamine to spot tests for explosives (1959) Analyst, 84, pp. 665-667 Almog, J., Klein, A., Tamiri, T., Shloosh, Y., Abramovich-Bar, S., A field diagnostic test for the improvised explosive urea nitrate (2005) J. Forensic Sci., 50, pp. 582-586 Doyle, J.M., Miller, M.L., McCord, B.R., McCollam, D.A., Mushrush, G.W., A multicomponent mobile phase for ion chromatography applied to the separation of anions from the residue of low explosives (2000) Anal. Chem., 72, pp. 2302-2307 Dicinoski, G.W., Shellie, R.A., Haddad, P.R., Forensic identification of inorganic explosives by ion chromatography (2006) Anal. Lett., 39, pp. 639-657 Tyrrell, É., Dicinoski, G.W., Hilder, E.F., Shellie, R.A., Breadmore, M.C., Pohl, C.A., Coupled reversed-phase and ion chromatographic system for the simultaneous identification of inorganic and organic explosives (2011) J. Chromatogr. A, 1218, pp. 3007-3012 Hargadon, K.A., McCord, B.R., Explosive residue analysis by capillary electrophoresis and ion chromatography (1992) J. Chromatogr. A, 602, pp. 241-247 McCord, B.R., Hargadon, K.A., Hall, K.E., Burmeister, S.G., Forensic analysis of explosives using ion chromatographic methods (1994) Anal. Chim. Acta, 288, pp. 43-56 Johns, C., Shellie, R.A., Potter, O.G., O'Reilly, J.W., Hutchinson, J.P., Guijt, R.M., Identification of homemade inorganic explosives by ion chromatographic analysis of post-blast residues (2008) J. Chromatogr. A, 1182, pp. 205-214 Doyle, J.M., McCord, B.R., Novel electrolyte for the analysis of cations in low explosive residue by capillary electrophoresis (1998) J. Chromatogr. B, 714, pp. 105-111 Sarazin, C., Delaunay, N., Varenne, A., Costanza, C., Eudes, V., Gareil, P., Capillary and microchip electrophoretic analyses of explosives and their residues (2010) Sep. Purif. Rev., 39, pp. 63-94 Hopper, K.G., LeClair, H., McCord, B.R., A novel method for analysis of explosives residue by simultaneous detection of anions and cations via capillary zone electrophoresis (2005) Talanta, 67, pp. 304-312 Hutchinson, J.P., Evenhuis, C.J., Johns, C., Kazarian, A.A., Breadmore, M.C., Macka, M., Identification of inorganic improvised explosive devices by analysis of postblast residues using portable capillary electrophoresis instrumentation and indirect photometric detection with a light-emitting diode (2007) Anal. Chem., 79, pp. 7005-7013 Cagan, A., Lu, D., Cizek, K., La Belle, J., Wang, J., Reliable, rapid and simple voltammetric detection of urea nitrate explosive (2008) Analyst, 133, pp. 585-587 Ferreira, F.J.O., Crispim, V.R., Silva, A.X., Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques (2010) Appl. Radiat. Isot., 68, pp. 1012-1017 Mass, J., Polo, A., Martinez, O., Lopez, W., Zurek, E.E., Esmeral, M., Identification of explosive substances through improved signals obtained by a portable Raman spectrometer (2012) Spectrosc. Lett., 45, pp. 413-419 Laboratory, S., (2010) Procedures for the Analysis of Explosive Evidence, , http://www.ncdoj.gov/About-DOJ/Crime-Lab/Crime-Laboratory-Documentation/explosives-procedures-2010-03-10.aspx, North Carolina, Available from Cheng, S., Dou, J., Wang, W., Chen, C., Hua, L., Zhou, Q., Dopant-assisted negative photoionization ion mobility spectrometry for sensitive detection of explosives (2013) Anal. Chem., 85, pp. 319-326 Chen, S., Wang, W., Zhou, Q., Chen, C., Peng, L., Hua, L., Fast switching of CO3-(H2O)(n) and O-2(-)(H2O)(n) reactant ions in dopant-assisted negative photoionization ion mobility spectrometry for explosives detection (2014) Anal. Chem., 86, pp. 2687-2693 Nehring, H., Thiebes, S., Bütfering, L., Röllgen, F.W., Cluster ion formation in thermospray mass spectrometry of ammonium salts (1993) Int. J. Mass Spectrom. Ion Processes, 128, pp. 123-132 Tamiri, T., Characterization of the improvised explosive urea nitrate using electrospray ionization and atmospheric pressure chemical ionization (2005) Rapid Commun. Mass Spectrom., 19, pp. 2094-2098 Zhao, X., Yinon, J., Characterization of ammonium nitrate by electrospray ionization tandem mass spectrometry (2001) Rapid Commun. Mass Spectrom., 15, pp. 1514-1519 Zhao, X., Yinon, J., Forensic identification of explosive oxidizers by electrospray ionization mass spectrometry (2002) Rapid Commun. Mass Spectrom., 16, pp. 1137-1146 Sigman, M.E., Armstrong, P., Analysis of oxidizer salt mixtures by electrospray ionization mass spectrometry (2006) Rapid Commun. Mass Spectrom., 20, pp. 427-432 Harris, G.A., Nyadong, L., Fernandez, F.M., Recent developments in ambient ionization techniques for analytical mass spectrometry (2008) Analyst, 133, pp. 1297-1301 Weston, D.J., Ambient ionization mass spectrometry: current understanding of mechanistic theory analytical performance and application areas (2010) Analyst, 135, pp. 661-668 Ifa, D.R., Wu, C., Ouyang, Z., Cooks, R.G., Desorption electrospray ionization and other ambient ionization methods: current progress and preview (2010) Analyst, 135, pp. 669-681 Alberici, R.M., Simas, R.C., Sanvido, G.B., Romao, W., Lalli, P.M., Benassi, M., Ambient mass spectrometry: bringing MS into the "real world" (2010) Anal. Bioanal. Chem., 398, pp. 265-294 Schwab, N.V., Porcari, A.M., Coelho, M.B., Schmidt, E.M., Jara, J.L., Visentainer, J.V., Easy dual-mode ambient mass spectrometry with Venturi self-pumping, canned air, disposable parts and voltage-free sonic-spray ionization (2012) Analyst, 137, pp. 2537-2540 Takats, Z., Wiseman, J.M., Gologan, B., Cooks, R.G., Mass spectrometry sampling under ambient conditions with desorption electrospray ionization (2004) Science, 306, pp. 471-473 Cody, R.B., Laramée, J.A., Durst, H.D., Versatile new ion source for the analysis of materials in open air under ambient conditions (2005) Anal. Chem., 77, pp. 2297-2302 McEwen, C.N., McKay, R.G., Larsen, B.S., Analysis of solids, liquids, and biological tissues using solids probe introduction at atmospheric pressure on commercial LC/MS instruments (2005) Anal. Chem., 77, pp. 7826-7831 Shiea, J., Huang, M.-Z., Hsu, H.-J., Lee, C.-Y., Yuan, C.-H., Beech, I., Electrospray-assisted laser desorption/ionization mass spectrometry for direct ambient analysis of solids (2005) Rapid Commun. Mass Spectrom., 19, pp. 3701-3704 Chen, H., Yang, S., Wortmann, A., Zenobi, R., Neutral desorption sampling of living objects for rapid analysis by extractive electrospray ionization mass spectrometry (2007) Angew. Chem. Int. Ed., 46, pp. 7591-7594 Haapala, M., Pól, J., Saarela, V., Arvola, V., Kotiaho, T., Ketola, R.A., Desorption atmospheric pressure photoionization (2007) Anal. Chem., 79, pp. 7867-7872 Haddad, R., Sparrapan, R., Eberlin, M.N., Desorption sonic spray ionization for (high) voltage-free ambient mass spectrometry (2006) Rapid Commun. Mass Spectrom., 20, pp. 2901-2905 Haddad, R., Milagre, H.M.S., Catharino, R.R., Eberlin, M.N., Easy ambient sonic-spray ionization mass spectrometry combined with thin-layer chromatography (2008) Anal. Chem., 80, pp. 2744-2750 Haddad, R., Regiani, T., Klitzke, C.F., Sanvido, G.B., Corilo, Y.E., Augusti, D.V., Gasoline, kerosene, and diesel fingerprinting via polar markers (2012) Energy Fuels, 26, pp. 3542-3547 Corilo, Y.E., Vaz, B.G., Simas, R.C., Lopes Nascimento, H.D., Klitzke, C.F., Pereira, R.C.L., Petroleomics by EASI(±) FT-ICR MS (2010) Anal. Chem., 82, pp. 3990-3996 Hughey, C.A., Hendrickson, C.L., Rodgers, R.P., Marshall, A.G., Elemental composition analysis of processed and unprocessed diesel fuel by electrospray ionization fourier transform ion cyclotron resonance mass spectrometry (2001) Energy Fuels, 15, pp. 1186-1193 Chattopadhyay, A.K., (1996) Explosives, , U.S. Patent, Inc IC (Ed.) Noy Michael John, S.V.J., (1999) ANFO Composition, , U.S. Patent, Ltd OAP (Ed.) Fox, R., Tankey, N.K., Victoria, H.R., (1974) Coated Ammonium Nitrate, , U.S. Patent, I.A. Ltd (Ed.) Eberlin, L.S., Haddad, R., Sarabia Neto, R.C., Cosso, R.G., Maia, D.R.J., Maldaner, A.O., Instantaneous chemical profiles of banknotes by ambient mass spectrometry (2010) Analyst, 135, pp. 2533-2539 Mueller, A., Weiss, S.C., Schulz, W., Seitz, W., Albert, R., Ruck, W.K.L., Combination of different liquid chromatography/mass spectrometry technologies for the identification of transformation products of rhodamine B in groundwater (2010) Rapid Commun. Mass Spectrom., 24, pp. 659-666 Keller, B.O., Suj, J., Young, A.B., Whittal, R.M., Interferences and contaminants encountered in modern mass spectrometry (2008) Anal. Chim. Acta, 627, pp. 71-81