dc.creatorSanches, Adelina
dc.creatorEtchebehere, Elba C.S.C.
dc.creatorMazzali, Marilda
dc.creatorAlves Filho, G.
dc.creatorLima, Mariana C.L.
dc.creatorSantos, Allan O.
dc.creatorRamos, Celso D.
dc.creatorCardinalli, Izilda
dc.creatorBillis, Athanase
dc.creatorCamargo, Edwaldo E.
dc.date2003-12-01
dc.date2014-07-18T18:02:01Z
dc.date2015-11-26T13:21:41Z
dc.date2014-07-18T18:02:01Z
dc.date2015-11-26T13:21:41Z
dc.date.accessioned2018-03-28T21:05:12Z
dc.date.available2018-03-28T21:05:12Z
dc.identifierInternational braz j urol. Sociedade Brasileira de Urologia, v. 29, n. 6, p. 507-516, 2003.
dc.identifier1677-5538
dc.identifierS1677-55382003000600005
dc.identifier10.1590/S1677-55382003000600005
dc.identifierhttp://dx.doi.org/10.1590/S1677-55382003000600005
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382003000600005
dc.identifierhttp://www.repositorio.unicamp.br/jspui/handle/REPOSIP/35291
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/35291
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1240009
dc.descriptionPURPOSE: Renal scintigraphy has been used for many years in the evaluation of renal transplants and can help in the diagnosis of graft complications, leading to prompt clinical management and preventing further deterioration of renal function. The purpose of this study was to evaluate the overall accuracy of renal scintigraphy with 99mTc-DTPA in the diagnosis of acute renal graft complications. MATERIALS AND METHODS: Seventy-six scintigraphic studies performed in 55 patients (ages ranging from 6 to 65 years), were reviewed. Scintigraphy results were compared to biopsies performed within 5 days of imaging. 99mTc-DTPA study was performed within a mean time of 19 days after kidney transplants. Dynamic images were performed in the anterior position of the abdomen and pelvis every 2 seconds for 80 seconds (flow phase) and every 15 seconds for 30 minutes (functional phase), after an intravenous injection of 370 MBq (10 mCi) of 99mTc-DTPA. RESULTS: The scintigraphic results were concordant with the biopsies in 86% of the cases studied. The sensitivities of renal scintigraphy for detection of acute tubular necrosis (ATN), acute rejection (AR) and cortical necrosis (CN) were 98%, 87% and 100%, respectively. Specificities and accuracies for detection of ATN, AR and CN were 89%, 86% and 100%, and 95%, 87% and 100%, respectively. CONCLUSION: Renal scintigraphy with 99mTc-DTPA showed a good overall accuracy in the detection of acute renal graft complications. It can be used as a reliable tool in the routine evaluation of these patients
dc.description507
dc.description516
dc.languageen
dc.publisherSociedade Brasileira de Urologia
dc.relationInternational braz j urol
dc.rightsaberto
dc.sourceSciELO
dc.subjectkidney
dc.subjectkidney transplantation
dc.subjectradionuclide imaging
dc.subjectgraft rejection
dc.subjectdiagnosis
dc.titleThe accuracy of 99mTc-DTPA scintigraphy in the evaluation of acute renal graft complications
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución