Artículos de revistas
Aneurisma toracoabdominal roto: modificação do circuito de perfusão visceral
Thoracoabdominal aneurysm rupture: a modification of the visceral perfusion circuit
Registro en:
Revista Brasileira de Cirurgia Cardiovascular. Sociedade Brasileira de Cirurgia Cardiovascular, v. 19, n. 4, p. 413-416, 2004.
0102-7638
S0102-76382004000400016
10.1590/S0102-76382004000400016
Autor
Rocha, Eduardo Faccini
Guillaumon, Ana Terezinha
Antunes, Nilson
Vieira, Reinaldo Wilson
Institución
Resumen
A patient with ruptured type IV thoracoabdominal aortic aneurysm (TAAA), underwent surgical treatment utilizing visceral perfusion assisted by a centrifugal pump and neonatal membrane oxygenator. This circuit allows visceral perfusion with oxygenated blood during the ischemic period and the fast infusion of intravenous volume after clamp removal. Paciente portador de aneurisma toracoabdominal (ATA) tipo lV, roto, submetido a tratamento cirúrgico utilizando perfusão visceral assistida por bomba centrífuga e oxigenador de membrana neonatal. Este circuito permite a perfusão visceral com sangue oxigenado, durante o período de isquemia, e infusão de volume rápido via venosa após a retirada da pinça. 413 416