dc.contributorAguilar Novillo, Paúl Fernando
dc.creatorUrdiales Flores, Cristian Gerardo
dc.date2016-02-16T19:19:07Z
dc.date2016-02-16T19:19:07Z
dc.date2016
dc.date.accessioned2018-03-14T20:16:57Z
dc.date.available2018-03-14T20:16:57Z
dc.identifierhttp://dspace.ucuenca.edu.ec/handle/123456789/23606
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1130883
dc.descriptionRESUMEN Estudio realizado en “Continental Tire Andina”, planta de manufactura de neumáticos ubicada en el Km 2.8 de la Panamericana Norte de la ciudad de Cuenca, de la mano de políticas de innovación, se llevó a cabo la Planificación y Diseño del Sistema de Gestión Energética para sus instalaciones, con el objetivo de medir su desempeño e identificar posibilidades de mejora en cuanto a activos eléctricos, térmicos, aire comprimido y agua de enfriamiento dentro de las instalaciones de producción de la empresa, para lo cual se utilizaron dos instancias: la primera basándonos en la determinación de estado inicial energético se realizó una auditoría de evaluación en la cual se abordaron cálculos físicos en las instalaciones permitiendo situar a la empresa bajo criterios técnicos normativos de energía eléctrica como CONELEC 004/01 y como gúia Normativa ISO 50001 de Eficiencia Energética poder realizar el diseño estructural del Sistema de Gestión Energética. Al ejecutar la Auditoria Energética de evaluación, se identificaron algunas oportunidades de mejora las cuales se enfatizan dentro de cinco ejes principales de accionar estos son: Optimización y Uso eficiente de Energía, Optimización de Energía Térmica en Prensas de Vulcanización, Optimización de Iluminación. Optimización de Temperatura de Unidades de Control, Utilización Eficiente de Equipos (compresores, bombas, intercambiadores de calor), con lo cual definimos las bases del Sistema de Gestión Energética. Palabras Clave Continental Tire Andina, eficiencia, eléctrica, térmica, sistemas, gestión.
dc.descriptionABSTRACT The study made in "Continental Tire Andina" tire manufacturing plant located at Km 2.8 of the Panamerican highway in the city of Cuenca, by the hand of policies of innovation, it held the Planning and Design of Energy Management System for its facilities, in order to measure performance and identify opportunities for improvement in the electrical, thermal, compressed air and cooling water within the production facilities of the company to which assets were used two instances: first determination was based on the initial state energy audit assessment in which physics calculations were addressed in the facilities allowing to place the company under regulatory technical criteria such as electricity and as a guide CONELEC 004/01 ISO 50001 Energy Efficiency was held to carry out the structural design of Energy Management System. Optimization and energy efficiency, optimization of thermal energy in curing presses, Lighting Optimization: When running the energy audit evaluation, some opportunities for improvement which are emphasized in five main areas of action these are identified. Optimization of temperature control units, efficient use of equipment (compressors, pumps, heat exchangers), which define the basis of the Energy Management System. Keywords Continental Tire Andina, efficiency, electrical, thermal, systems management.
dc.descriptionMagíster en Planificación y Gestión Energéticas
dc.formatapplication/pdf
dc.languagespa
dc.relationTM4;983
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/
dc.sourceinstname:Universidad de Cuenca
dc.sourcereponame:Repositorio Digital de la Universidad de Cuenca
dc.subjectGESTION ENERGETICA
dc.subjectNEUMATICOS
dc.subjectPLANTA DE MANUFACTURA
dc.subjectPOLITICAS DE INNOVACION
dc.subjectEFICIENCIA ENERGETICA
dc.subjectTESIS DE MAESTRIA EN PLANIFICACION Y GESTION ENERGETICAS
dc.titleDiseño de un sistema de gestión energética basado en la norma ISO 50001 de eficiencia energética en Continental Tire Andina
dc.typeTesis


Este ítem pertenece a la siguiente institución