dc.contributor | Moscoso Correa, José Joaquín | |
dc.contributor | Morales Sanmartín, Jaime Rodrigo | |
dc.creator | Becerra Pino, Iván Oliver | |
dc.date | 2013-07-26T14:19:55Z | |
dc.date | 2013-07-26T14:19:55Z | |
dc.date | 2013 | |
dc.date.accessioned | 2018-03-14T19:21:45Z | |
dc.date.available | 2018-03-14T19:21:45Z | |
dc.identifier | http://dspace.ucuenca.edu.ec/handle/123456789/4008 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/1112247 | |
dc.description | Antecedentes: El ultrasonido prenatal permite el cálculo directo del tamaño del fetal y la predicción de su peso con un intervalo de confianza del 95%. Es importante conocer con anticipación el peso fetal, porque permite incrementar las probabilidades de sobrevivir que tiene un RN.- Objetivos: determinar la correlación y la concordancia entre el peso fetal estimado por ecografía y el peso real obtenido al nacer.- Materiales y métodos: Se realizó un diseño descriptivo observacional y transversal, en una muestra de 509 pacientes en las cuales se valoró la correlación y concordancia entre el peso fetal estimado por ecografía y el peso real obtenido por báscula de los recién nacidos a término en el Hospital Vicente Corral Moscoso; con un protocolo de estudio que incluyó: la historia clínica materna, equipo de ultrasonido marca TOSHIBA XARIO modelo TA510 y balanza mecánica HEALTH O METER PROFESSIONAL. -Resultados: Se demostró que el índice de correlación entre el peso fetal estimado y el peso real fue de 0.726 con un margen de error de 4 %. -El análisis de regresión lineal expresa que por cada gramo obtenido en el peso ecográfico, el peso real se incrementará en 0.81 gramos.-au | |
dc.description | Background: The prenatal ultrasound allows direct calculation of fetal size and weight prediction with a confidence interval of 95%. It is important to know ahead fetal weight, because it allows to increase the odds of having an RN survive.
Objectives: To determine the correlation and agreement between ultrasound-estimated fetal weight and the actual weight obtained at birth.
Materials and Methods: This was a descriptive cross-sectional observational design, in a sample of 509 patients in which we evaluated the correlation and agreement between ultrasound-estimated fetal weight and the actual weight of scale obtained by term infants in the Vicente Corral Moscoso hospital, with a study protocol that included: maternal medical history, ultrasound equipment Xario TOSHIBA TA510 and mechanical scale model HEALTH O METER PROFESSIONAL.
Results: It was shown that the correlation index between the estimated fetal weight and the actual weight was 0726 with a margin of error of 4%.
The linear regression analysis for each gram expresses that obtained in ultrasound weight, the actual weight increase by 0.81 grams.
KEYWORDS: FETAL WEIGHT, BIRTH WEIGHT, INFANT, LOW BIRTH WEIGHT, WEIGHT GAIN, PRENATAL ULTRASONOGRAPHY | |
dc.description | Especialista en Imagenología | |
dc.description | Cuenca | |
dc.format | application/pdf | |
dc.language | spa | |
dc.relation | MEDI;9 | |
dc.rights | openAccess | |
dc.rights | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | |
dc.source | instname:Universidad de Cuenca | |
dc.source | reponame:Repositorio Digital de la Universidad de Cuenca | |
dc.subject | PESO FETAL | |
dc.subject | PESO AL NACER | |
dc.subject | RECIEN NACIDO DE BAJO PESO | |
dc.subject | AUMENTO DE PESO | |
dc.subject | ULTRASONOGRAFIA PRENATAL | |
dc.subject | HOSPITAL VICENTE CORRAL MOSCOSO | |
dc.title | Correlación y concordancia entre el peso fetal estimado por ecografía y el peso real obtenido por báscula de los recién nacidos a término en el Hospital Vicente Corral Moscoso durante el 2012 | |
dc.type | Tesis | |