dc.contributorRamos, Juan Marcelo
dc.contributorCalderón, Hugo
dc.contributorAndrade, Mónica
dc.creatorGuanga Inca, Ulises Rigoberto
dc.date2016-01-18T17:19:28Z
dc.date2016-01-18T17:19:28Z
dc.date2015-06
dc.date.accessioned2018-03-13T18:19:34Z
dc.date.available2018-03-13T18:19:34Z
dc.identifierGuanga Inca, Ulises Rigoberto. (2015). Diseño de un Sistema de Tratamiento de aguas servidas de los pozos de captación en la parroquia rural Matus del cantón Penipe. Escuela Superior Politécnica de Chimborazo. Riobamba.
dc.identifierhttp://dspace.espoch.edu.ec/handle/123456789/4357
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1061079
dc.descriptionEn la presente investigación se ejecutó el diseño del Sistema de Tratamiento de aguas servidas de los pozos de captación en la Parroquia Rural Matus del cantón Penipe provenientes del sistema de alcantarillado minimizando así los impactos ambientales producidos al río Matus. Con el fin de realizar esta investigación se empleó el método experimental, se realizó muestras de aguas compuestas para su caracterización físico – química y microbiológicos, los que se analizaron en el laboratorio de Servicios Analíticos Químicos Microbiológicos (SAQMIC), Análisis Técnicos de la ESPOCH y de Servicios Ambientales de la UNACH, determinando las variables que se encuentran fuera de los límites permisibles en base al TULSMA. En los estudios de caracterización del agua servida se manipularon Métodos Normalizados APHA, AWWA, WPCF 17 - 21 ed. y HACH, los mismos que identificaron cinco parámetros físico-químicos-microbiológicos fuera de los límites permisibles, siendo éstos: demanda química de oxígeno (DQO), demanda bioquímica de oxígeno en cinco días (DBO5), fosfatos, sólidos sedimentables, coliformes fecales las variables de investigación para el diseño del sistema de tratamiento. Para mermar las variables fueras del límite permisible se efectuó el dimensionamiento por medio de cálculos de ingeniería del sistema de tratamiento de aguas servidas, cuyo diseño y área constituye de: cribado (canal con rejillas) con 0,77 m2, coagulador-floculador con agitación con 28,33 m2, sedimentador rectangular con 31,47 m2, lecho de secado de lodos con 3,33 m2 y tanque de desinfección con 10,5 m2. El sistema de tratamiento propuesto para aguas servidas en la Parroquia Matus, garantizará la no contaminación del Río Matus y cumplirá con la normativa del Texto Unificado de Legislación Secundaria del Ministerio del Ambiente (TULSMA) del Ecuador. Sería importante la implementación de este sistema de tratamiento de aguas servidas con su técnico capacitado para que no se observe estos focos de contaminación.
dc.descriptionIn this research the design of waste water treatment system of collection wells was carried out in the Rural Parish Matus of canton Penipe comes from sewage system thus minimizing environmental impacts produced to the river Matus. In order to perform this research it was used the experimental method, and water samples were realized for their physical- chemical and microbiological characterization, which were analyzed in the analytical chemical microbiological service laboratory (SAQMIC), Technical Analysis of ESPOCH and Environmental Services of UNACH determining the variables that are outside the permissible limits based on Unified Text of the Secondary Legislation of the Ministry of Environment (TULAS). Standardized Methods APHA, AWWA, WPCF 17-21 ed. and HACH, were employed in studies of characterization of waste water, the same that identify five physical-chemical- microbiological parameters outside the permissible limits, being the following: chemical oxygen demand (COD), biochemical oxygen demand in five days (BOD5), phosphates, settleable solids, fecal coliforms, the research variables for the design of the treatment system. To diminish the variables outside the permissible limit, the sizing was performed by engineering calculation of waste water treatment system, whose design and area constitute: screening (channel with grids) with 0,77 m2, coagulator-flocculator with stirring with 28,33 m2, rectangular sedimentation tank with 31,47 m2, sludge drying bed with 3,33 m2 and disinfection tank with 10,5 m2. The proposed waste water treatment system in Parish Matus will ensure no contamination of the river Matus and comply the rules of the Unified Text of the Secondary Legislation of the Ministry of Environment (TULAS) of Ecuador. It would be important to implement this system of wastewater treatment system with a trained technician to prevent sources of pollution.
dc.languagespa
dc.publisherEscuela Superior Politécnica de Chimborazo
dc.relationUDCTFC;96T00296
dc.rightsopenAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/
dc.subjectAMBIENTE
dc.subjectTRATAMIENTO DE AGUAS SERVIDAS
dc.subjectPARÁMETROS QUÍMICOS
dc.subjectSEDIMENTADOR RECTANGULAR
dc.subjectCRIBADO
dc.subjectCOAGULADOR-FLOCULADOR
dc.subjectPARÁMETROS FÍSICOS
dc.subjectMATUS [PARROQUIA RURAL]
dc.subjectPENIPE [CANTON]
dc.titleDiseño de un Sistema de Tratamiento de aguas servidas de los pozos de captación en la parroquia rural Matus del cantón Penipe.
dc.typeTesis


Este ítem pertenece a la siguiente institución