Buscar
Mostrando ítems 1-10 de 1325
Rod length influence in torque measurement of SPT-T test
(2007-09-18)
Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. ...
Rod length influence in torque measurement of SPT-T test
(2007-09-18)
Since Ranzini suggested supplementing the SPT test with measurement of the torque required to turn the split spoon sampler after driving, many Brazilian engineers have been using this in the design of pile foundations. ...
Análise do torque de aperto em uniões parafusadas
(Universidade Estadual Paulista (Unesp), 2019-02-28)
As uniões parafusadas possuem uma grande aplicação na indústria, mas quando se pensa na utilização de parafusos existe uma impressão de ser um elemento de simples dimensionamento e de fácil aplicação. No entanto, o ...
Influence of Angular Thrust in the Measurement of Torque in the SPT-T
(Ios Press, 2015-01-01)
Skin friction of piles can be calculated with the torque measurement in the Standard Penetration Test, SPT-T, proposed by [1]. The purpose of this paper is to provide understating of the influence of angular thrust and ...
Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study
(WILEY-BLACKWELL PUBLISHING, INC, 2009)
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical ...
Desenvolvimento e avaliação de padrão de torque para calibração de torquímetros em três faixas de medição
(Universidade Federal do Rio Grande do NorteBRUFRNPrograma de Pós-Graduação em Engenharia MecânicaTecnologia de Materiais; Projetos Mecânicos; Termociências, 2007-09-03)
The continuous development of instruments and equipment used as tools or torque measurement in the industry is demanding more accurate techniques in the use of this kind instrumentation, including development of metrological ...
Evaluation of Torque Maintenance of Abutment and Cylinder Screws With Morse Taper Implants
(Lippincott Williams & Wilkins, 2012-11-01)
The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention ...
Evaluation of Torque Maintenance of Abutment and Cylinder Screws With Morse Taper Implants
(Lippincott Williams & Wilkins, 2012-11-01)
The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention ...
Theoretical and experimental evaluation of the influence of the length of drill rods in the SPT-T test
(2010-01-01)
The influence of soil drill rod length on the N value in the SPT-T test has been studied extensively by Mello (1971), Schmertmann & Palacios (1979), Odebrecht et al. (2002) and Cavalcante (2002). This paper presents an ...