Buscar
Mostrando ítems 1-10 de 341
Mineral trioxide aggregate but not light-cure mineral trioxide aggregate stimulated mineralization
(Elsevier B.V., 2008-01-01)
The purpose of this study was to evaluate the subcutaneous response of rat connective tissue to light-cure MTA and Angelus MTA. These materials were placed in polyethylene and dentin tubes and implanted into dorsal connective ...
Comparison of subcutaneous connective tissue responses among three different formulations of gutta-percha used in thermatic techniques.
(1990-07-01)
A study of the subcutaneous connective tissue response of 24 white rats to three different formulations of gutta-percha was undertaken. The prepared specimens were examined under the light microscope after intervals of 7, ...
Comparison of subcutaneous connective tissue responses among three different formulations of gutta-percha used in thermatic techniques.
(1990-07-01)
A study of the subcutaneous connective tissue response of 24 white rats to three different formulations of gutta-percha was undertaken. The prepared specimens were examined under the light microscope after intervals of 7, ...
Reação do tecido conjuntivo subcutâneo e de feridas incisas em contacto com gaze furacinada: estudo histológico
(1979-12-01)
Strips of gauze and furacin gauze were implanted into the subcutaneous space and employed as dressing of dorsal incisions of albino rats. The animals were sacrificed after 24 hours, 2, 5, and 7 post-operative days. The ...
Biocompatibility of RealSeal, its primer and AH Plus implanted in subcutaneous connective tissue of rats
(Faculdade de Odontologia de BauruPorto Alegre, 2011)
Objective: This study tested rat connective tissue response to RealSeal, RealSeal primer or AH Plus after 7, 15, 30, 60 and 90 days of implantation. Material and methods: Thirty Wistar rats had subcutaneous sockets created ...
Biocompatibility of RealSeal, its primer and AH Plus implanted in subcutaneous connective tissue of rats
(Faculdade de Odontologia de BauruPorto Alegre, 2011)
Objective: This study tested rat connective tissue response to RealSeal, RealSeal primer or AH Plus after 7, 15, 30, 60 and 90 days of implantation. Material and methods: Thirty Wistar rats had subcutaneous sockets created ...
Subcutaneous tissue reaction to modified Portland cement (CPM)
(2012-01-01)
Introduction: The aim of this study was to evaluate the rat subcutaneous tissue response to implanted polyethylene tubes filled with Modified Portland Cement (CPM®) (Egeo S.R.L., Buenos Aires, Argentina) compared with ...
Mineral trioxide aggregate but not light-cure mineral trioxide aggregate stimulated mineralization
(Elsevier B.V., 2008-01-01)
The purpose of this study was to evaluate the subcutaneous response of rat connective tissue to light-cure MTA and Angelus MTA. These materials were placed in polyethylene and dentin tubes and implanted into dorsal connective ...
Histological study of rat subcutaneous connective-tissue reaction to the implant to 10-percent metronidazole ointment used to dry socket trestment
(American Association for Dental Research (AADR), 1995-03-01)
Histological study of rat subcutaneous connective-tissue reaction to the implant to 10-percent metronidazole ointment used to dry socket trestment
(American Association for Dental Research (AADR), 1995-03-01)