Buscar
Mostrando ítems 1-10 de 178
A strain gauge analysis of microstrain induced by various splinting methods and acrylic resin types for implant impressions
(2012-01-01)
The aim of this study was to investigate the level of microstrain that is exerted during polymerization of acrylic resins used for splinting during implant impressions. Material and Methods: Two acrylic resins (GC Pattern ...
A Strain Gauge Analysis of Microstrain Induced by Various Splinting Methods and Acrylic Resin Types for Implant Impressions
(Quintessence Publishing Co Inc, 2012-03-01)
Purpose: The aim of this study was to investigate the level of microstrain that is exerted during polymerization of acrylic resins used for splinting during implant impressions. Material and Methods: Two acrylic resins (GC ...
A Strain Gauge Analysis of Microstrain Induced by Various Splinting Methods and Acrylic Resin Types for Implant Impressions
(Quintessence Publishing Co Inc, 2012-03-01)
Purpose: The aim of this study was to investigate the level of microstrain that is exerted during polymerization of acrylic resins used for splinting during implant impressions. Material and Methods: Two acrylic resins (GC ...
Comparative evaluation of the efficacy of occlusal splints fabricated in centric relation or maximum intercuspation in temporomandibular disorders patients
(Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru, 2009-01-01)
Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might ...
Comparative evaluation of the efficacy of occlusal splints fabricated in centric relation or maximum intercuspation in temporomandibular disorders patients
(2009-01-01)
Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might ...
The Effect of Splint Material Rigidity in Implant Impression Techniques
(Quintessence Publishing Co Inc, 2010-11-01)
Purpose This in vitro study compared the dimensional accuracy of two impression techniques Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant supported pros theses Materials and ...
The Effect of Splint Material Rigidity in Implant Impression Techniques
(Quintessence Publishing Co Inc, 2010-11-01)
Purpose This in vitro study compared the dimensional accuracy of two impression techniques Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant supported pros theses Materials and ...
The effect of splint material rigidity in implant impression techniques
(2010-01-01)
Purpose: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. Materials and ...
The Effect of Splint Material Rigidity in Implant Impression Techniques
(Quintessence Publishing Co Inc, 2014)
Comparative evaluation of the efficacy of occlusal splints fabricated in centric relation or maximum intercuspation in temporomandibular disorders patients
(Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru, 2013)