Buscar
Mostrando ítems 1-10 de 92
Voltage responsivity of pyroelectric sensor
(Elsevier B.V., 1999-09-28)
Composites polymer-ceramic using castor oil-based polyurethane (PU) as non-ferroelectric matrix and Lead Zirconate Titanate (PZT) as ceramic powder have been prepared at thin films form by spin coating. The samples are ...
Voltage responsivity of pyroelectric sensor
(Elsevier B.V., 1999-09-28)
Composites polymer-ceramic using castor oil-based polyurethane (PU) as non-ferroelectric matrix and Lead Zirconate Titanate (PZT) as ceramic powder have been prepared at thin films form by spin coating. The samples are ...
The Application of Pyroelectric Sensors in the Measurementof X-Ray Intensity and Ultrasonic Transducer Output Power: a Review
(2022-06-01)
The biological effects of the signals produced by X-ray and ultrasound equipment strongly depend on their intensity. Some articles were published addressing the use of pyroelectric sensors to measure the intensity of X-rays ...
Measurement of orthovoltage X-ray intensity with a lithium niobate transducer
(2009-12-01)
A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a ...
Dielectric and pyroelectric properties of a composite of ferroelectric ceramic and polyurethane
(Springer, 2002-05-01)
Flexible piezo- and pyroelectric composite was made in the thin film form by spin coating. Lead Zirconate Titanate (PZT) ceramic powder was dispersed in a castor oil-based polyurethane (PU) matrix, providing a composite ...
Dielectric and pyroelectric properties of a composite of ferroelectric ceramic and polyurethane
(Springer, 2002-05-01)
Flexible piezo- and pyroelectric composite was made in the thin film form by spin coating. Lead Zirconate Titanate (PZT) ceramic powder was dispersed in a castor oil-based polyurethane (PU) matrix, providing a composite ...
Pyroelectric composite film for X-ray intensity detection
(ABM, ABC, ABPol, 2012-04-01)
Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. ...
Voltage responsivity of pyroelectric sensor
(Elsevier B.V., 2014)
Study of pyroelectric activity of PZT/PVDF-HFP composite
(ABM, ABC, ABPol, 2003-12)
Flexible, free-standing piezo and pyroelectric composite with 0 to 3 connectivity was made up from Lead Zirconate Titanate (PZT) powder and poly(vinylidene fluoride-hexafluoropropylene) (PVDF-HFP) copolymer. The pyroelectric ...
Pyroelectric composite film for X-ray intensity detection
(ABM, ABC, ABPol, 2012-04-01)
Composite material obtained with modified lead titanate (Pz34) ferroelectric ceramic and polyether-ether-ketone (PEEK) polymer matrix was used as sensitive component to measure X-ray intensity in a novel detection system. ...