Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals
(Blackwell PublishingOxfordInglaterra, 2006)
Using frequency-doubling perimetry to detect optic neuropathy in patients with Graves` orbitopathy
(SPRINGER TOKYO, 2008)
to test the ability of frequency-doubling technology (FDT) perimetry to detect dysthyroid optic neuropathy (DON). Fifteen eyes of 15 patients with DON and 15 healthy control eyes were studied. Eligible eyes had a diagnosis ...
Influence of blue light spectrum filter on short-wavelength and standard automated perimetries
(Conselho Brasileiro de Oftalmologia, 2006-10-01)
PURPOSE: To evaluate the influence of a blue light spectrum filter (BLSF), similar in light spectrum transmittance to the intraocular lens Acrysof NaturalTM, on standard automated perimetry (SAP) and short-wavelength ...
Structure-function Relationships Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
(LIPPINCOTT WILLIAMS & WILKINSPHILADELPHIA, 2012)
Purpose: To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP). Methods: Four hundred ...
Structure-function Relationships Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
(Lippincott Williams & Wilkins, 2012-01-01)
Purpose: To evaluate the relationship between glaucomatous structural damage assessed by the Cirrus Spectral Domain OCT (SDOCT) and functional loss as measured by standard automated perimetry (SAP).Methods: Four hundred ...
Structure-Function Correlations in Glaucoma Using Matrix and Standard Automated Perimetry Versus Time-Domain and Spectral-Domain OCT Devices
(Assoc Research Vision Ophthalmology Inc, 2014-05-01)
PURPOSE. We examined the structure-function relationship between two perimetric tests, the frequency doubling technology (FDT) matrix and standard automated perimetry (SAP), and two optical coherence tomography (OCT) devices ...
Importância da perimetria manual cinética na avaliação de pacientes com glaucoma avançado
(Sociedade Brasileira de Oftalmologia, 2011-02-01)
PURPOSE: To evaluate the importance of Goldmann manual kinetic perimetry (MKP) in glaucomatous patients with advanced visual field loss in automated static perimetry (ASP) with Humphrey perimeter (HP). METHODS: The MKP ...
Visual field losses in workers exposed to mercury vapor
(ACADEMIC PRESS INC ELSEVIER SCIENCE, 2008)
Visual field losses associated with mercury (Hg) exposure have only been assessed in patients exposed to methylmercury. Here we evaluate the automated visual field in 35 ex-workers (30 males; 44.20+/-5.92 years) occupationaly ...
Learning effect of standard automated perimetry in healthy individuals
(Conselho Brasileiro de Oftalmologia, 2008-08-01)
PURPOSE: To evaluate the learning effect in standard automated perimetry using SITA strategy, central 24-2 program, possible associated factors and spatial distribution in individuals with no perimetry experience. METHODS: ...