Buscar
Mostrando ítems 1-10 de 76
PZT FOR MEASURING ENERGY FLUENCE RATE of X-RAY USED IN SUPERFICIAL CANCER THERAPY
(Taylor & Francis Inc, 2010-01-01)
A PZT detector is used for measuring the energy fluence rate of X-ray pulses produced by superficial cancer therapy equipment (orthovoltage range). The instrument consists of a pyroelectric sensor, a low-noise high-sensitivity, ...
PZT FOR MEASURING ENERGY FLUENCE RATE of X-RAY USED IN SUPERFICIAL CANCER THERAPY
(Taylor & Francis Inc, 2010-01-01)
A PZT detector is used for measuring the energy fluence rate of X-ray pulses produced by superficial cancer therapy equipment (orthovoltage range). The instrument consists of a pyroelectric sensor, a low-noise high-sensitivity, ...
Measurement of orthovoltage X-ray intensity with a lithium niobate transducer
(2009-12-01)
A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a ...
Two thermal methods to measure the energy fluence of a brief exposure of diagnostic x rays
(1992-07-03)
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly ...
Two thermal methods to measure the energy fluence of a brief exposure of diagnostic x rays
(1992-07-03)
This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly ...
Measurement of orthovoltage X-ray intensity with a lithium niobate transducer
(2009-12-01)
A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a ...
PZT FOR MEASURING ENERGY FLUENCE RATE of X-RAY USED IN SUPERFICIAL CANCER THERAPY
(Taylor & Francis Inc, 2014)
Implementação de um sistema eletrônico para medir taxa de fluência de energia de radiação na faixa de radioterapia com sensor piroelétrico
(Universidade Estadual Paulista (Unesp), 2011-02-25)
Sensores piroelétricos podem ser utilizados para medir a taxa de fluência de energia (intensidade) da radiação X na faixa de diagnóstico médico e de ortovoltagem. Neste trabalho, foi implementado um sistema eletrônico que ...