Buscar
Mostrando ítems 1-10 de 2753
Voltage Control in Low Voltage Distribution Networks with High Penetration Photovoltaic System
(Ieee, 2017-01-01)
Photovoltaic generators can provide several benefits for distribution networks, such as power loss reduction, and improvements in voltage level. However, high penetration of these generators can cause voltage rise problems ...
Voltage control in low voltage distribution networks with high penetration photovoltaic system
(2017-12-01)
Photovoltaic generators can provide several benefits for distribution networks, such as power loss reduction, and improvements in voltage level. However, high penetration of these generators can cause voltage rise problems ...
Voltage regulator modeling for the three-phase power flow in distribution networks
(2008-12-01)
In this paper a three-phase power flow for electrical distribution systems considering different models of voltage regulators is presented. A voltage regulator (VR) is an equipment that maintains the voltage level in a ...
Voltage regulator modeling for the three-phase power flow in distribution networks
(2008-12-01)
In this paper a three-phase power flow for electrical distribution systems considering different models of voltage regulators is presented. A voltage regulator (VR) is an equipment that maintains the voltage level in a ...
A physical approach of the test voltage function for evaluation of the impulse parameters in lightning impulse voltages with superimposed oscillations and overshoots
(Institute of Electrical and Electronics Engineers, 2016-10)
The introduction of the test voltage function or k-factor in IEC 60060-1 Ed. 3 has been an important step to ensure reproducibility and traceability in high voltage tests techniques for lightning impulses with superposed ...
Analysis of Dynamic Voltage Support Schemes for PV Generators Implemented in Latin America
(Institute of Electrical and Electronics Engineers, 2020-04)
The levels of renewable power, particularly PV, injected into different electrical systems in Latin America, bring with them a series of fundamental technical changes that need to be addressed. Among them, power quality ...
Location of single line-to-ground faults on distribution feeders using voltage measurements
(2006-12-01)
This paper proposes a dedicated algorithm for lation of single line-to-ground faults in distribution systems. The proposed algorithm uses voltage and current phasors measured at the substation level, voltage magnitudes ...
Influence of excitation system control modes on the allowable penetration level of distributed synchronous generators
(Ieee-inst Electrical Electronics Engineers IncPiscatawayEUA, 2005)