Buscar
Mostrando ítems 1-8 de 8
Elaboration and characterization of the electrodeposited phosphates masses doped with various ions on stainless steel
(Virtual Institute of Physics, 2014-06)
The present paper is focused on elaboration of phosphate masses with good molar ratios on SS 316L, with fluoride, Zn2+ and Cu2+ as dopant ions, using an electrochemical procedure and also the attempt to select the best ...
Producción de películas de nitruro-titanio-aluminio-vanadio (TiAlV)N variando la temperatura del sustrato por la técnica PAPVD
(2007)
Se depositaron películas de (TiAlV)N sobre sustratos de acero 304 y H13 por medio de la técnica PAPVD por arco pulsado, variando la temperatura del sustrato en un rango desde temperatura ambiente hasta 300°C. Los recubrimientos ...
Implementación de una fuente de arcos pulsados para la producción de recubrimientos duros de TiN
(2004)
En este trabajo se hace referencia a la implementación de una fuente de arcos pulsados, que ha sido acoplada a un sistema de deposición de recubrimientos duros, utilizando la técnica de deposición física en fase vapor ...
An Expandable Prosthesis with Dual Cage-and-Plate Function in a Single Device for Vertebral Body Replacement: Clinical Experience on 14 Cases with Vertebral Tumors
(2010)
An expandable vertebral body prosthesis with dual cage-and-plate function in a single device (JR prosthesis) was designed to test the hypothesis that this modular system can provide the biomechanical requirements for ...
An expandable prosthesis with dual cage-and-plate function in a single device for vertebral body replacement: The clinical experience on 14 consecutive cases with vertebral tumors
(2011)
Aim. The aim of this paper was to test the hypothesis that an expandable prosthesis with dual cage-and-plate function can provide immediate and durable spine stabilization after corpectomy. Methods. We designed an expandable ...
An expandable prosthesis with dual cage-and-plate function in a single device for vertebral body replacement: The clinical experience on 14 consecutive cases with vertebral tumors
(2011)
Aim. The aim of this paper was to test the hypothesis that an expandable prosthesis with dual cage-and-plate function can provide immediate and durable spine stabilization after corpectomy. Methods. We designed an expandable ...
An Expandable Prosthesis with Dual Cage-and-Plate Function in a Single Device for Vertebral Body Replacement: Clinical Experience on 14 Cases with Vertebral Tumors
(2010)
An expandable vertebral body prosthesis with dual cage-and-plate function in a single device (JR prosthesis) was designed to test the hypothesis that this modular system can provide the biomechanical requirements for ...