Buscar
Mostrando ítems 1-10 de 67
Evaluation of Bone Loss and Success / Failure of Titanium Implant Positioning with Immediate and Late Charge, Used in Full Arch Restorations at 12 Months of Implant.
(2016)
The purpose of this study was to evaluate the bone level and the success and failure of loaded implants positioned immediately after extraction for full-arch restorations and compare the results obtained with implants ...
Evaluation of Bone Loss and Success / Failure of Titanium Implant Positioning with Immediate and Late Charge, Used in Full Arch Restorations at 12 Months of Implant.
(2016)
The purpose of this study was to evaluate the bone level and the success and failure of loaded implants positioned immediately after extraction for full-arch restorations and compare the results obtained with implants ...
The influence of bone quality on the biomechanical behavior of full-arch implant-supported fixed prostheses
(Elsevier B.V., 2014-04-01)
We evaluated the influence of bone tissue type on stress distribution in full-arch implant-supported fixed prostheses using a three-dimensional finite element analysis. Stresses in cortical and trabecular bones were also ...
Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible - A computed tomography-based three-dimensional finite element analysis
(2013-04-26)
A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of ...
Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible - A computed tomography-based three-dimensional finite element analysis
(2013-04-26)
A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of ...
Non-linear 3D finite element analysis of full-arch implant-supported fixed dentures
(Elsevier B.V., 2014-05-01)
Despite the necessity for faster clinical protocols for immediate loading of implant-supported dentures, there is a lack of biomechanical studies to confirm the rigid splinting effectiveness. We compared the stress in ...
Computer-guided implant surgery and full-arch immediate loading with prefabricated-metal framework-provisional prosthesis created from a 3D printed model
(Facultad de Medicina y Ciencia, 2019)
Objective In this article, we describe the planning phase and clinical procedure where a CAD CAM 3D printed master model was utilized to create a prefabricated-titanium reinforced-fixed provisional prosthesis for a full-arch ...
Computer-guided implant surgery and full-arch immediate loading with prefabricated—metal framework—provisional prosthesis created from a 3D printed model
(2019-05-01)
Objective: In this article, we describe the planning phase and clinical procedure where a CAD CAM 3D printed master model was utilized to create a prefabricated—titanium reinforced—fixed provisional prosthesis for a full-arch ...