Análise do escoamento de HFC-134a em tubos capilares usando o modelo de dois fluidos
(1996-03-01)
This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The capillary tube is considered straight and horizontal. The flow is ...
Análise do escoamento de HFC-134a em tubos capilares usando o modelo de dois fluidos
(1996-03-01)
This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The capillary tube is considered straight and horizontal. The flow is ...
Foam flow of oil-refrigerant R12 mixture in a small diameter tube
(Associação Brasileira de Engenharia e Ciências Mecânicas - ABCM, 2006-12)
This paper presents an experimental investigation of the mineral oil ISO VG10-refrigerant R12 mixture flow with foam formation in a straight horizontal 3.22 mm ID, 6.0 m long tube. An experimental apparatus was designed ...
Transient flow of the oil-refrigerant mixture through the radial clearance in rolling piston compressors
(1999-12-01)
Unsteady flow of oil and refrigerant gas through radial clearance in rolling piston compressors has been modeled as a heterogeneous mixture, where the properties are determined from the species conservation transport ...
Transient flow of the oil-refrigerant mixture through the radial clearance in rolling piston compressors
(1999-12-01)
Unsteady flow of oil and refrigerant gas through radial clearance in rolling piston compressors has been modeled as a heterogeneous mixture, where the properties are determined from the species conservation transport ...
Pressure drop correlation for oil-refrigerant R134a mixture flashing flow in a small diameter tube
(Elsevier B.V., 2009-05-01)
This paper presents an experimental investigation of the ester oil ISO VG10/refrigerant R134a mixture flashing flow in a 6.0 m long, 3.22 mm ID tube, which is one of the primary steps towards the construction of a methodology ...
Pressure drop correlation for oil-refrigerant R134a mixture flashing flow in a small diameter tube
(Elsevier B.V., 2009-05-01)
This paper presents an experimental investigation of the ester oil ISO VG10/refrigerant R134a mixture flashing flow in a 6.0 m long, 3.22 mm ID tube, which is one of the primary steps towards the construction of a methodology ...
Mathematical modeling of the ester oil-refrigerant R134A mixture two-phase flow with foam formation through a small diameter tube
(Abcm Brazilian Soc Mechanical Sciences & Engineering, 2011-07-01)
This work presents a mathematical modeling to study the ester oil ISO VG-10-refrigerant R134a mixture two-phase flow with foam formation through a 3.22 mm ID tube. Based on experimental visualization results, the flow is ...