Buscar
Mostrando ítems 1-10 de 308
Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling
(2011-01-01)
Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. ...
Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling
(2011-01-01)
Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. ...
A new intraoral device to facilitate preparation of the guide plane for removable dental prostheses
(2012-01-01)
The design of the ParalAB device facilitates transfer of the path of insertion from the diagnostic cast to the mouth quickly and efficiently.
A new intraoral device to facilitate preparation of the guide plane for removable dental prostheses
(2012-01-01)
The design of the ParalAB device facilitates transfer of the path of insertion from the diagnostic cast to the mouth quickly and efficiently.
Effect of Passive Fit Absence in the Prosthesis/Implant/Retaining Screw System: A Two-Dimensional Finite Element Analysis
(Lippincott Williams & Wilkins, 2009-11-01)
The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels ...
Effect of Passive Fit Absence in the Prosthesis/Implant/Retaining Screw System: A Two-Dimensional Finite Element Analysis
(Lippincott Williams & Wilkins, 2009-11-01)
The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels ...
Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels
(Elsevier Sci LtdOxfordInglaterra, 2013)
Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method
(KOREAN ACAD PROSTHODONTICSSEOUL, 2013-08-02)
PURPOSE. Adequate passive-fitting of one-piece cast 3-element implant-supported frameworks is hard to achieve. This short communication aims to present an alternative method for section of one-piece cast frameworks and for ...