Buscar
Mostrando ítems 1-10 de 1872
Sensitivity analysis for overload-relief in transmission lines using an implicitly coupled method (CRIC)
(2006-12-01)
The restructuring of energy markets to provide free access to the networks and the consequent increase of the number of power transactions has been causing congestions in transmission systems. As consequence, the networks ...
Sensitivity analysis for overload-relief in transmission lines using an implicitly coupled method (CRIC)
(2006-12-01)
The restructuring of energy markets to provide free access to the networks and the consequent increase of the number of power transactions has been causing congestions in transmission systems. As consequence, the networks ...
Real-time estimation of transmission line impedance based on modal analysis theory
(2011-12-09)
The objective of this paper is to show a methodology to estimate the longitudinal parameters of transmission lines. The method is based on the modal analysis theory and developed from the currents and voltages measured at ...
Real-time estimation of transmission line impedance based on modal analysis theory
(2011-12-09)
The objective of this paper is to show a methodology to estimate the longitudinal parameters of transmission lines. The method is based on the modal analysis theory and developed from the currents and voltages measured at ...
Comparison Between Traditional Single-phase Auto Reclosing And Adaptive Technique Based On Harmonic Content Measurement
(Inst Engineering Technology-IETHertford, 2017)
Simplified procedure to estimate the resistance parameters of transmission lines
(2013-09-01)
An alternative and simplified procedure is described to estimate the longitudinal resistances of transmission lines based on the real-time load profile. This method proposes to estimate the resistance parameters from the ...
The use of current transformers for noise detection due to sparking in insulators strings in high voltage transmission lines
(2010-12-31)
In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between ...
The use of current transformers for noise detection due to sparking in insulators strings in high voltage transmission lines
(2010-12-31)
In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between ...