Buscar
Mostrando ítems 1-10 de 17975
Distributed generation modelling for unbalanced three-phase power flow calculations in smart grids
(2011-05-31)
Distributed Generators (DG) are generally modeled as PQ or PV buses in power flow studies. But in order to integrate DG units into the distribution systems and control the reactive power injection it is necessary to know ...
Distributed generation modelling for unbalanced three-phase power flow calculations in smart grids
(2011-05-31)
Distributed Generators (DG) are generally modeled as PQ or PV buses in power flow studies. But in order to integrate DG units into the distribution systems and control the reactive power injection it is necessary to know ...
Optimal allocation of distributed generators providing reactive power support ancillary service
(2011-10-05)
Problems as voltage increase at the end of a feeder, demand supply unbalance in a fault condition, power quality decline, increase of power losses, and reduction of reliability levels may occur if Distributed Generators ...
Pricing of reactive power support provided by distributed generators in transmission systems
(2011-10-05)
Distributed Generation, microgrid technologies, two-way communication systems, and demand response programs are issues that are being studied in recent years within the concept of smart grids. At some level of enough ...
Pricing of reactive power support provided by distributed generators in transmission systems
(2011-10-05)
Distributed Generation, microgrid technologies, two-way communication systems, and demand response programs are issues that are being studied in recent years within the concept of smart grids. At some level of enough ...
Technology assessment for power quality mitigation devices - Micro-DVR case study
(2008-12-23)
This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase ...
Technology assessment for power quality mitigation devices - Micro-DVR case study
(2008-12-23)
This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase ...
A note on the local power of the LR, Wald, score and gradient tests
(INST MATHEMATICAL STATISTICSCLEVELAND, 2012)
This paper examines the local power of the likelihood ratio, Wald, score and gradient tests under the presence of a scalar parameter, phi say, that is orthogonal to the remaining parameters. We show that some of the ...