Análise e dimensionamento de cortinas de estacas moldadas no local
(Universidade Tecnológica Federal do ParanáToledo, 2012-12-10)
Due to increasing occupancy rate in urban areas is increasingly common use of basements in buildings, and therefore implementation of containment structures is required. Very common, curtain poles molded in place is a ...
Análise comparativa de soluções de fundação para um edifício localizado em Toledo-PR
(Universidade Tecnológica Federal do ParanáToledoBrasilEngenharia CivilUTFPR, 2021-11-30)
The present work consists of a technical and economic comparative analysis of different foundation solutions from a sizing and budget, looking for the most suitable one for a building located in Toledo-PR. The possible ...
Projeto geotécnico de fundação predial em estaca
(Universidade Tecnológica Federal do ParanáCuritibaBrasilGraduação em Engenharia CivilUTFPR, 2017-12-06)
The present study intends to execute a geotechnical project of building foundation in stakes from a set of document analysis, such as reports of geotechnical investigation, load plan and additional reports. Aoki-Velloso ...
Comparativo entre modalidades de estacas de contenção para obras prediais vizinhas em Curitiba-PR
(Universidade Tecnológica Federal do ParanáCuritibaBrasilEspecialização em Gerenciamento de ObrasUTFPR, 2017-06-15)
The objective of this monograph is to compare the pile retaining wall modalities by drilled piles and by augercast piles. Two neighboring construction sites were choosen from the same construction company in the city of ...
Estudo da interação solo-estaca sujeito a carregamento horizontal em ambientes submersos
(Universidade Tecnológica Federal do ParanáCuritibaPrograma de Pós-Graduação em Engenharia Civil, 2012-12-21)
This work aims to make a study of the soil-pile interaction in submerged environments. For the analysis we used the following conditions: two types of piles, concrete pile and composite pile (steel pipe filled with concrete), ...
Analytical solution for the soil-structure interaction of a non-uniform section pile on non-homogeneous soil conditions
(Universidad Nacional de ColombiaMedellín - Minas - Maestría en Ingeniería - GeotecniaFacultad de MinasMedellín, ColombiaUniversidad Nacional de Colombia - Sede Medellín, 2022-12)
Non-prismatic piles are typically used in cases where large lateral loads must be resisted.
In many applications, these elements are implemented in partially and fully-embedded
layered soils to improve the load transfer ...
Estudo da influência do tipo de estaca no dimensionamento de blocos de coroamento
(Universidade Tecnológica Federal do ParanáToledoBrasilEngenharia CivilUTFPR, 2016-11-10)
Análise numérica de blocos sobre duas estacas considerando atrito lateral entre as estacas e o soloNumerical analyses of caps with two piles considering lateral friction between piles and soil
(Universidade Federal de UberlândiaBrasilPrograma de Pós-graduação em Engenharia Civil, 2019)
Estudo paramétrico de forças horizontais em tubulões curtos
(Universidade Tecnológica Federal do ParanáCampo MouraoBrasilDepartamento Acadêmico de Construção CivilEngenharia CivilUTFPR, 2018-06-21)
With the development of society and the need for more and more complex constructions, we saw the urgency of considerations in the analyzes that cater to special uses such as off-shore structures, bridges, among others. ...