Buscar
Mostrando ítems 1-10 de 217
LEFT-VENTRICULAR MAXIMAL SYSTOLIC ELASTANCE CALCULATED BY A COMBINATION OF M-MODE ECHOCARDIOGRAPHY AND STANDARD MANOMETRY
(Associação Brasileira de Divulgação Científica (ABRADIC), 1991-01-01)
1. A method for obtaining the end-systolic left ventricular (LV) pressure-diameter and stress-diameter relationships in man was critically analyzed.2. Pressure-diameter and stress-diameter relationships were determined ...
LEFT-VENTRICULAR MAXIMAL SYSTOLIC ELASTANCE CALCULATED BY A COMBINATION OF M-MODE ECHOCARDIOGRAPHY AND STANDARD MANOMETRY
(Associação Brasileira de Divulgação Científica (ABRADIC), 1991-01-01)
1. A method for obtaining the end-systolic left ventricular (LV) pressure-diameter and stress-diameter relationships in man was critically analyzed.2. Pressure-diameter and stress-diameter relationships were determined ...
LEFT-VENTRICULAR MAXIMAL SYSTOLIC ELASTANCE CALCULATED BY A COMBINATION OF M-MODE ECHOCARDIOGRAPHY AND STANDARD MANOMETRY
(Associação Brasileira de Divulgação Científica (ABRADIC), 2014)
Left ventricular maximal systolic elastance calculated by a combination of M-mode echocardiography and standard manometry.
(1991-01-01)
1. A method for obtaining the end-systolic left ventricular (LV) pressure-diameter and stress-diameter relationships in man was critically analyzed. 2. Pressure-diameter and stress-diameter relationships were determined ...
Relações pressão-diâmetro e esforço-diâmetro do ventrículo esquerdo em seres humanos. Padronização e análise crítica do método.
(1990-06-01)
PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter ...
Relações pressão-diâmetro e esforço-diâmetro do ventrículo esquerdo em seres humanos. Padronização e análise crítica do método.
(1990-06-01)
PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter ...
Global REACH 2018: The carotid artery diameter response to the cold pressor test is governed by arterial blood pressure during normoxic but not hypoxic conditions in healthy lowlanders and Andean highlanders
(Wiley, 2020)
New Findings: What is the central question of this study? What is the impact of oxygen on the circulatory responses to an isocapnic cold pressor test (CPT) in lowlanders and Andean highlanders? What is the main finding and ...
Model to design drip hose lateral line using two spacing between emitters
(2012-12-01)
The use of non-pressure compensating drip hose in horticultural and annual cycle fruits is growing in Brazil. In this case, the challenge for designers is getting longer lateral lines with high values of uniformity. The ...
Model to design drip hose lateral line using two spacing between emitters
(2012-12-01)
The use of non-pressure compensating drip hose in horticultural and annual cycle fruits is growing in Brazil. In this case, the challenge for designers is getting longer lateral lines with high values of uniformity. The ...