Buscar
Mostrando ítems 1-10 de 28
Biomechanical Performance of Flexible Intramedullary Nails With End Caps Tested in Distal Segmental Defects of Pediatric Femur Models
(LIPPINCOTT WILLIAMS & WILKINSPHILADELPHIA, 2012)
Background: Unstable distal femoral fractures in children are challenging lesions with restricted surgical options for adequate stabilization. Elastic nails have become popular for treating femoral shaft fractures, yet ...
Osteossíntese das fraturas diafisárias da criança com hastes intramedulares flexíveis
(Sociedade Brasileira de Ortopedia e Traumatologia, 2008)
O tratamento de algumas das fraturas da criança tem sofrido modificações nos últimos anos, com o objetivo de obtenção de resultados mais satisfatórios, restrição do tempo de incapacidade e para melhor corresponder às ...
Treatment of the humeral shaft fractures - minimally invasive osteosynthesis with bridge plate versus conservative treatment with functional brace: study protocol for a randomised controlled trial
(Biomed Central Ltd, 2013-08-07)
Background: Humeral shaft fractures account for 1 to 3% of all fractures in adults and for 20% of all humeral fractures. Non-operative treatment is still the standard treatment of isolated humeral shaft fractures, although ...
Manejo fisioterapéutico en el post operatorio de fijación in situ para deslizamiento epifisiario femoral unilateral
(FisioterapiaEscuela de Medicina y Ciencias de la Salud, 1999)
Use of the Ilizarov external fixator in the treatment of patients with Ollier's disease
(Lippincott Williams & Wilkins, 2001-01-01)
The authors present the results of treatment of 10 patients with Oilier's disease using the Ilizarov technique. The Ilizarov device was used to treat leg length discrepancy and to enhance the conversion of chondroma cartilage ...
A novel device for greater precision and safety in open-wedge high tibial osteotomy: cadaveric study
(2020-02-01)
Introduction: The complications of the open-wedge osteotomy technique (slope, hypo- and hypercorrection and fractures) are related to difficulties in the control of the open-wedge angle during surgery. Materials and methods: ...
Multilayer silica-methacrylate hybrid coatings prepared by sol-gel on stainless steel 316L: Electrochemical evaluation
(Elsevier Science Sa, 2008-02)
AISI 316L stainless steel is a biocompatible alloy used in prosthetic devices for many years. However this alloy tends to suffer localized corrosion and needs external fixation to hard tissues. This work describes the ...
Use of extensible internal device in the femur of young dogs
(Schattauer Gmbh-verlag Medizin Naturwissenschaften, 2008-01-01)
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, ...
Use of extensible internal device in the femur of young dogs
(Schattauer Gmbh-verlag Medizin Naturwissenschaften, 2008-01-01)
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, ...
Use of extensible internal device in the femur of young dogs
(SCHATTAUER GMBH-VERLAG MEDIZIN NATURWISSENSCHAFTEN, 2008)
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, ...