Buscar
Mostrando ítems 1-10 de 74
Biocompatibility analysis of Bioglass® 45S5 and Biosilicate® implants in the rabbit eviscerated socket
(2012-06-01)
Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right ...
Biocompatibility analysis of Bioglass® 45S5 and Biosilicate® implants in the rabbit eviscerated socket
(2012-06-01)
Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right ...
Gelatinous polyethylene in the treatment of the anophthalmic cavity
(2002-08-23)
PURPOSE: Gelatinous polyethylene (GP) has been used as an orbital implant to evaluate volume maintenance and tissue reaction in the anophthalmic socket in a rabbit model. METHODS: Twenty-eight Norfolk white rabbits underwent ...
Gelatinous polyethylene in the treatment of the anophthalmic cavity
(2002-08-23)
PURPOSE: Gelatinous polyethylene (GP) has been used as an orbital implant to evaluate volume maintenance and tissue reaction in the anophthalmic socket in a rabbit model. METHODS: Twenty-eight Norfolk white rabbits underwent ...
Condutas para reparação da cavidade anoftálmica no Brasil
(2012-12-01)
Purpose: To determine the most common approach to repair the anophthalmic socket in Brazil, and to compare the data with the trends in other countries. Methods: Exploratory study using electronic questionnaire sent by ...
Condutas para reparação da cavidade anoftálmica no Brasil
(Conselho Brasileiro de Oftalmologia, 2012-11-01)
Purpose: To determine the most common approach to repair the anophthalmic socket in Brazil, and to compare the data with the trends in other countries.Methods: Exploratory study using electronic questionnaire sent by ...
Condutas para reparação da cavidade anoftálmica no Brasil
(Conselho Brasileiro de Oftalmologia, 2012-11-01)
Purpose: To determine the most common approach to repair the anophthalmic socket in Brazil, and to compare the data with the trends in other countries.Methods: Exploratory study using electronic questionnaire sent by ...
Cohesive silicone gel implants with smooth, textured or polyurethane-coated surface to restore volume in eviscerated sockets
(Taylor & Francis Inc, 2018-01-01)
The purpose of this article is to evaluate the three different surface coating on cohesive silicone gel implants in eviscerated rabbit eye sockets. Forty-five albino rabbits underwent right eye evisceration and received ...