Buscar
Mostrando ítems 1-10 de 2786
Determination of Mg (II) in biodiesel by adsorptive stripping voltammetry at a mercury film electrode in the presence of sodium thiopentone
(2013-01-01)
A mercury film electrode was used to determine Mg (II) in biodiesel by adsorptive stripping voltammetry in presence of sodium thiopentone. A linear response was obtained for Mg (II) in the concentration range of 6.0 × 10-7 ...
Determination of Mg (II) in biodiesel by adsorptive stripping voltammetry at a mercury film electrode in the presence of sodium thiopentone
(2013-01-01)
A mercury film electrode was used to determine Mg (II) in biodiesel by adsorptive stripping voltammetry in presence of sodium thiopentone. A linear response was obtained for Mg (II) in the concentration range of 6.0 × 10-7 ...
Artificial neural networks study of the catalytic reduction of resazurin. Stopped-flow injection kinetic-spectrophotometric determination of Cu(II) and Ni(II)
(Elsevier Science, 2005-12)
An artificial neural network (ANN) procedure was used in the development of a catalytic spectrophotometric method for the determination of Cu(II) and Ni(II) employing a stopped-flow injection system. The method is based ...
Multivariate quality control studies applied to Ca(II) and Mg(II) determination by a portable method
(Wiley-Blackwell, 1998-09-01)
A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the ...
Multivariate quality control studies applied to Ca(II) and Mg(II) determination by a portable method
(Wiley-Blackwell, 1998-09-01)
A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the ...
Multivariate quality control studies applied to Ca(II) and Mg(II) determination by a portable method
(1998-01-01)
A portable or field test method for simultaneous spectrophotometric determination of calcium and magnesium in water using multivariate partial least squares (PLS) calibration methods is proposed. The method is based on the ...
A simple and green analytical method for determination of copper(II) in whisky and sugarcane spirit by diffuse reflectance spectroscopy
(2016-02-28)
In this paper we propose a new, fast, simple, economical, portable and environmentally friendly analytical methodology for the determination of copper(II) ions in whisky and sugarcane spirit, using the combination of ...
Development of method for the speciation of inorganic iron in wine samples
(2007)
In this paper, we proposed a procedure for the determination of iron(II) and total iron in wine samples employing molecular absorption spectrophotometry. The ligand used is 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol ...
Consumo de Imipenem 500 mg / Cilastatina 500 mg. en pacientes hospitalizados del Hospital II Chocope – EsSalud, abril 2018 – marzo 2019
(Universidad Nacional de TrujilloPE, 2021)
El presente trabajo de investigación, es un estudio descriptivo, de corte transversal y
retrospectivo cuyo objetivo es determinar el consumo de IMIPENEM 500mg
/CILASTATINA 500mg. En los Servicios de Hospitalización ...