Buscar
Mostrando ítems 1-10 de 342
Relation between Insertion Torque and Implant Stability Quotient: A Clinical Study
(2021-01-01)
Objectives This study aimed to assess the relation between the insertion torque and implant stability quotient (ISQ recorded immediately and 6 months after implant placement). Materials and Methods Twenty-five patients ...
Mechanical Performance of Cylindrical and Dual-Core Pedicle Screws After Repeated Insertion
(LIPPINCOTT WILLIAMS & WILKINSPHILADELPHIA, 2012)
Study Design. Ex vivo study of the mechanical performance of cylindrical and dual-core pedicle screws after insertion, removal, and reinsertion in the same hole. Objective. To evaluate the effect of repeated use of same ...
The effect of implant design on insertion torque and immediate micromotion
(WILEY-BLACKWELLMALDEN, 2013-08-02)
Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting ...
The effect of implant design on insertion torque and immediate micromotion
(Wiley-Blackwell, 2012-01-01)
Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting ...
The effect of implant design on insertion torque and immediate micromotion
(Wiley-Blackwell, 2012-01-01)
Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting ...
Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque
(2018-06-01)
Background: Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. Purpose: The purpose of the present in vitro study was to evaluate the mechanical ...
Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study
(WILEY-BLACKWELL PUBLISHING, INC, 2009)
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical ...
Healing of implants installed in over- or under-prepared sites: an experimental study in dogs
(Wiley-Blackwell, 2015-04-01)
ObjectiveTo study bone healing at implants installed with different insertion torques.Material and methodsIn six Labrador dogs, all mandibular premolars and first molars were extracted. After 4months of healing, flaps were ...