Buscar
Mostrando ítems 1-10 de 3559
SEM-EDS and biomechanical evaluation of implants with different surface treatments: An initial study
(2009-12-01)
Aim: Alterations in implant surfaces can affect periimplant bone formation and shorten the healing time. The goal of the present study was a comparative scanning electron microscopy (SEM)/energy dispersive spectrometry ...
SEM-EDS and biomechanical evaluation of implants with different surface treatments: An initial study
(2009-12-01)
Aim: Alterations in implant surfaces can affect periimplant bone formation and shorten the healing time. The goal of the present study was a comparative scanning electron microscopy (SEM)/energy dispersive spectrometry ...
Histometric analysis and topographic characterization of cp Ti implants with surfaces modified by laser with and without silica deposition
(Wiley-Blackwell, 2014-11-01)
Biologic behavior of the bone tissue around implants with four different surfaces was evaluated. The surfaces were: modified by laser (LS); modified by laser with sodium silicate deposition (SS); and commercially available ...
Implant-based factor as possible risk for peri-implantitis
(2019-01-01)
Peri-implantitis is currently a topic of major interest in implantology. Considered one of the main reasons of late implant failure, there is an emerged concern whether implant characteristics could trigger inflammatory ...
Comparison of the primary and secondary stability of implants with anodized surfaces and implants treated by acids: A split-mouth randomized controlled clinical trial
(2016-01-01)
Purpose: The objective of this randomized controlled clinical split-mouth trial was to compare anodized implant surfaces and implant surfaces modified by acid etching in terms of primary and secondary stability. Materials ...
Relationship between the surface chemical composition of implants and contact with the substrate
(2015)
The purpose of the study was to use scanning electron microscopy and energy dispersive x-ray spectrometry to assess possible morphologic and chemical changes after performing double-insertion and pullout tests of implants ...
Histologic and biomechanical evaluation of 2 resorbable-blasting media implant surfaces at early implantation times
(2013-08-01)
This study evaluated 3 implant surfaces in a dog model: (1) resorbable-blasting media + acid-etched (RBMa), alumina-blasting + acid-etching (AB/AE), and AB/AE + RBMa (hybrid). All of the surfaces were minimally rough, and ...
Histologic and biomechanical evaluation of 2 resorbable-blasting media implant surfaces at early implantation times
(2013-08-01)
This study evaluated 3 implant surfaces in a dog model: (1) resorbable-blasting media + acid-etched (RBMa), alumina-blasting + acid-etching (AB/AE), and AB/AE + RBMa (hybrid). All of the surfaces were minimally rough, and ...
Histomorphometric Evaluation of Bioceramic Molecular Impregnated and Dual Acid-Etched Implant Surfaces in the Human Posterior Maxilla
(WILEY-BLACKWELL PUBLISHING, INC, 2010)
Background: Physical and bioceramic incorporation surface treatments at the nanometer scale showed higher means of bone-to-implant contact (BIC) and torque values compared with surface topography at the micrometer scale; ...
In Vivo Osteogenesis and In Vitro Streptococcus mutans Adherence: Porous-Surfaced Cylindrical Implants vs Rough-Surfaced Threaded Implants
(Quintessence Publishing Co Inc, 2013-11-01)
Purpose: To analyze and compare bone apposition at the interface of commercially available rough-surfaced, threaded implants with porous-surfaced, cylindrical implants after several healing periods in a rabbit model. In ...