Buscar
Mostrando ítems 1-10 de 61
Fatigue apparatus for geometrically complex non-standardized specimens
(2009-01-01)
Standard Test Methods (e.g. ASTM, DIN) for materials characterization in general, and for fatigue in particular, do not contemplate specimens with complex geometries, as well as the combination of axial and in-plane bending ...
Fatigue apparatus for geometrically complex non-standardized specimens
(2009-01-01)
Standard Test Methods (e.g. ASTM, DIN) for materials characterization in general, and for fatigue in particular, do not contemplate specimens with complex geometries, as well as the combination of axial and in-plane bending ...
Cyclic Fatigue Resistance of Rotary Nickel-Titanium Instruments Submitted to Nitrogen Ion Implantation
(ELSEVIER SCIENCE INC, 2010)
Introduction: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. Methods: ...
Issues on the mean stress effect in fretting fatigue of a 7050-T7451 Al alloy posed by new experimental data
(2009-11)
The aims of this work are: (i) to produce new experimental data for fretting fatigue considering the presence of a mean bulk stress and (ii) to assess two design methodologies against failure by fretting fatigue. Tests on ...
Análise cinético-funcional comparativa no procedimento de exodontia via fórceps convencional (utilizando empunhadura reversa) e ergofórceps
(Universidade Tecnológica Federal do ParanáCuritibaPrograma de Pós-Graduação em Engenharia Biomédica, 2013-09-26)
Ergonomics applied to the dental activity aims to rationalize the procedures, avoiding unnecessary fatigue to the professional, while still offering safety and comfort to the patient. The extraction, among the several ...
Caracterização de um handgrip com mola e um bracelete instrumentados com sensores FBG e aplicação dos dispositivos em um estudo de caso de fadiga muscular
(Universidade Tecnológica Federal do ParanáCuritibaBrasilPrograma de Pós-Graduação em Engenharia Elétrica e Informática IndustrialUTFPR, 2022-04-29)
This work presents the characterization of a spring handgrip and a forearm band instrumented with sensors based on optical fiber Bragg gratings (FBGs) and application of these devices in a case study to assess muscle ...
Flusser, the inverted prophet: the criticism of consumer society and the apparatus of the military dictatorship in correspondence between Vilém Flusser and José BuenoFlusser, o profeta invertido: a crítica à sociedade de consumo e ao aparelho da ditadura militar em correspondência de Vilém Flusser e José Bueno
(Universidade Federal do Rio Grande do Sul, 2020)
Specific Measurement Of Tethered Running Kinetics And Its Relationship To Repeated Sprint Ability
(DE GRUYTER OPEN LTDWARSAW, 2015)