External Hexagon and Internal Hexagon in Straight and Offset Implant Placement: Strain Gauge Analysis
(Lippincott Williams & Wilkins, 2009-12-01)
Purpose: The objective of this in vitro study was to quantify the strain development of external hexagon. and internal hexagon implant-supported partial prostheses in. straight and offset implant placement configurations.Materials ...
External Hexagon and Internal Hexagon in Straight and Offset Implant Placement: Strain Gauge Analysis
(Lippincott Williams & Wilkins, 2009-12-01)
Purpose: The objective of this in vitro study was to quantify the strain development of external hexagon. and internal hexagon implant-supported partial prostheses in. straight and offset implant placement configurations.Materials ...
Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration
(Lippincott Williams & Wilkins, 2011-04-01)
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse ...
Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration
(Lippincott Williams & Wilkins, 2011-04-01)
Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse ...
Photoelastic Analysis of Biomechanical Behavior of Single and Multiple Fixed Partial Prostheses With Different Prosthetic Connections
(Lippincott Williams & Wilkins, 2011-11-01)
The aim of this study was to evaluate the stress distribution on external hexagon, internal hexagon, and Morse taper implant in single and 3-unit implant-supported fixed partial prostheses (FPPs) using photoelasticity. Six ...
External Hexagon and Internal Hexagon in Straight and Offset Implant Placement: Strain Gauge Analysis
(Lippincott Williams & Wilkins, 2014)
Comparison of the Morse Cone Connection with the Internal Hexagon and External Hexagon Connections Based on Microleakage - Review
(2021-01-01)
The gap formed at the abutment-implant interface brings about a bacterial colonization. In addition, a bacterial reservoir can be established within the implant. The build-up of microorganisms around the implant can cause ...
Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration
(Lippincott Williams & Wilkins, 2014)
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2010-01-01)
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and ...
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2010-01-01)
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and ...