Buscar
Mostrando ítems 1-10 de 116
Dry-contact microelectrode membranes for wireless detection of electrical phenotypes in neonatal mouse hearts
(Springer, 2015-04)
Continuous monitoring of aberrant electrical rhythms during heart injury and repair requires prolonged data acquisition. We hereby developed a wearable microelectrode membrane that could be adherent to the chest of neonatal ...
Análises da arritmia sinusal respiratóriaAnalyses of respiratory sinus arrhythmia
(Universidade Federal de UberlândiaBrasilPrograma de Pós-graduação em Engenharia Elétrica, 2020)
The effect of glycerol on signal supression during electrospray ionization analysis of proteins
(2004-06-04)
The effect of salts, detergents and chaotropic agents on mass spectrometric analysis are relatively well understood, mainly due to their actions decreasing the performance of ESI interface in mass spectrometric analysis. ...
The effect of glycerol on signal supression during electrospray ionization analysis of proteins
(2004-06-04)
The effect of salts, detergents and chaotropic agents on mass spectrometric analysis are relatively well understood, mainly due to their actions decreasing the performance of ESI interface in mass spectrometric analysis. ...
Sistema portátil para monitoramento contínuo da atividade elétrica cardíaca
(Universidade Tecnológica Federal do ParanáCuritibaDepartamento Acadêmico de Eletrônica, 2013-04-25)
In the cardiac activity, electrical signals that propagate through the corporal structures can be caught on the skin surface. The record of these signals is the electrocardiogram (ECG). Arrhythmia and ventricular bradycardia, ...
Heart rate variability analysis during a dehydration protocol on athletes
(INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INC., 2016-08-30)
Athletes usually start the training with normal body water content, and then they dehydrate during exercise. The water deficit may contribute to increased heart rate and therefore impaired heart rate variability (HRV) ...
Diferentes frequências da estimulação elétrica nervosa transcutânea sobre o balanço simpato-vagal
(Universidade Federal de Santa MariaBrasilUFSMCentro de Ciências da Saúde, 2015-07-07)
Transcutaneous electrical nerve stimulation (TENS) is a electrotherapeutic mode used in physical medicine and rehabilitation, particularly for pain control. This therapeutic approach also has cardiovascular effects that ...
Implementación de un prototipo para la medición del pulso cardíaco mediante procesamiento de vídeo en la tarjeta de desarrollo JETSON TX1
(Instituto Tecnológico de Costa Rica, 2018)
Non-invasive techniques for vital signs monitoring have been developing in the last
years due to interdisciplinary fields like the computer vision and artificial intelligence. So, in
RidgeRun Engineering, there is a need ...