Time-Domain Electromechanical Impedance for Structural Health Monitoring
(European Assoc Structural Dynamics, 2011-01-01)
Electromechanical impedance (EMI) technique is a very simple method that can be usefulness in most of Non-Destructive Evaluation (NDE) and Structural Health Monitoring (SHM) systems. A common application of EMI methods is ...
Time-domain electromechanical impedance for Structural Health Monitoring
(2011-01-01)
Electromechanical impedance (EMI) technique is a very simple method that can be usefulness in most of Non-Destructive Evaluation (NDE) and Structural Health Monitoring (SHM) systems. A common application of EMI methods is ...
Induction machine small-signal impedance for stability studies using dynamic phasor modeling
(IEEE, 2017)
The presence of both electronic-converter-based and rotating-machine-based energy sources in microgrids poses a challenge for its stable operation. Most of the stability studies in microgrids have been focused on the ...
On the dual side of operational dynamics: A formulation, applications, and implications of the impedance model
(2016-03-03)
This paper studies the operational dynamics of a structure in steady state under a given source. It is based on the duality of operational structural dynamics, which states that the structure in operation can be viewed ...
Human interaction dynamics for its use in mobile robotics: Impedance control for leader-follower formation
(Institute of Electrical and Electronics Engineers, 2017-10)
A complete characterization of the behavior in human-robot interactions (HRI) includes both: the behavioral dynamics and the control laws that characterize how the behavior is regulated with the perception data. In this ...
Impedance spectroscopy applied to the fast wounding dynamics of an electrical wound-healing assay in mammalian cells
(IOP Publishing, 2015-06-25)
Electrical wound-healing assays are often used as a means to study in vitro cell migration and proliferation. In such analysis, a cell monolayer that sits on a small electrode is electrically wounded and its spectral ...
A dynamic time-temperature-dependent process for thermal oxidation of Sn leading to SnOx thin films: Impedance spectroscopy study
(World Scientific Publ Co Pte Ltd, 2020-07-30)
Tin dioxide (SnO2) thin films are obtained from resistive evaporation of metallic Sn followed by thermal oxidation at different temperatures in the range 200-500 degrees C. Results show that, besides the thickness of the ...
Lumped Element Modeling of a Flexible Manipulator System
(Ieee-inst Electrical Electronics Engineers Inc, 2015-04-01)
This paper is concerned with a modeling method that can be used for an experimental identification of a dynamic system. More specifically, an equivalent lumped element system is presented to represent in a unique and exact ...