Pressure field in the cathode-anode region of a high-power klystron amplifier
(2004-08-30)
The pressure field of a high-power klystron amplifier in the cathode and anode region was investigated. The investigation was performed using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial ...
Pressure field in the cathode-anode region of a high-power klystron amplifier
(2004-08-30)
The pressure field of a high-power klystron amplifier in the cathode and anode region was investigated. The investigation was performed using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial ...
Coaxial cross-diffusion through carbon nantoubes
(American Chemical Society, 2009-12)
We present results from nonequilibrium molecular dynamics experiments describing the relaxation of local concentrations at two reservoirs, initially filled with water (W) and acetonitrile (ACN), as they become connected ...
Long range Casimir force induced by transverse electromagnetic modes
(American Physical Society, 2009-12)
We consider the interaction of two perfectly conducting plates of arbitrary shape that are inside a nonsimply connected cylinder with transverse section of the same shape. We show that the existence of transverse electromagnetic ...
Pressure field along the axis of a high-power klystron amplifier
(Institute of Electrical and Electronics Engineers (IEEE), 2003-01-01)
The pressure field in a high-power klystron amplifier is investigated to scale the ionic vacuum pump used to maintain the ultra high-vacuum in the device in order to increase its life-time. The investigation is conducted ...
Pressure field along the axis of a high-power klystron amplifier
(Institute of Electrical and Electronics Engineers (IEEE), 2003-01-01)
The pressure field in a high-power klystron amplifier is investigated to scale the ionic vacuum pump used to maintain the ultra high-vacuum in the device in order to increase its life-time. The investigation is conducted ...
Pressure field along the axis of a high-power klystron amplifier
(2003-12-01)
The pressure field in a high-power klystron amplifier is investigated to scale the ionic vacuum pump used to maintain the ultra high-vacuum in the device in order to increase its life-time. The investigation is conducted ...
Pressure field along the axis of a high-power klystron amplifier
(Institute of Electrical and Electronics Engineers (IEEE), 2014)
Implantación y Calibración del Presiómetro Ménard para estimación de capacidad de soporte y deformabilidad de suelos en cimentaciones de proyectos ICE.
(Instituto Tecnológico de Costa Rica, 2007)
The pressuremeter test is used in situ soil testing.
The test consist of placing a cylindrical probe in a
borehole with a diameter that allows the probe to
be in contact with the soil.
The active part of the pressuremeter ...