Buscar
Mostrando ítems 1-10 de 533
Are more restrictive food cadmium standards justifiable health safety measures or opportunistic barriers to trade? An answer from economics and public health
(Elsevier, 2008)
In the past, Cd regulations have imposed trade restrictions on foodstuffs from some developing countries seeking to access markets in the developed world and in recent years, there has been a trend towards imposing more ...
Determination of cadmium and lead in table salt by sequential multi-element flame atomic absorption spectrometry
(Elsevier, 2005-02-28)
In the present paper, a simultaneous pre-concentration procedure for the sequential determination of cadmium and lead in table salt samples using flame atomic absorption spectrometry is proposed. This method is based on ...
Age-related differential sensitivity to cadmium in Hyalella curvispina (Amphipoda) and implications in ecotoxicity studies
(Elsevier Inc, 2010-02)
The standardization of toxicity tests requires the selection of the most suitable test species and their developmental stages, as well as the selection of the appropriate assay matrix and the evaluation of the sensitivity ...
Flow-through photometric sensor for the determination of cadmium at toe nanogram per millilitre level
(1993)
A sensor for the determination of cadmium based on retention of the Cdl4″ complex on a QAE Sephadex resin located in the flow-cell of a conventional photometric detector and on subsequent complex displacement reaction with ...
Water phytoremediation of cadmium and copper using Azolla filiculoidesLam. in a hydroponic system
(WILEY-BLACKWELL, 111 RIVER ST, HOBOKEN 07030-5774, NJ USA, 2013)
Simultaneous pre-concentration procedure for the determination of cadmium and lead in drinking water employing sequential multi-element flame atomic absorption spectrometry
(2007)
In this paper is proposed a simultaneous pre-concentration procedure using cloud point extraction for the determination of cadmium and lead in drinking water employing sequential multi-element flame atomic absorption ...
Application of Box–Behnken design in the optimisation of an on-line pre-concentration system using knotted reactor for cadmium determination by flame atomic absorption spectrometry
(2005)
The present paper proposes an on-line pre-concentration system for cadmium determination in drinking water using flame atomic absorption spectrometry (FAAS). Cadmium(II) ions are retained as 1-(2-pyridylazo)-2-naphthol ...
Calorimetric study of the adducts CdBr2 center dot nL (n=1 and 2; L = ethyleneurea and propyleneurea)
(Elsevier Science BvAmsterdamHolanda, 2002)
Application of ultrasonically modified cloud point extraction method for simultaneous enrichment of cadmium and lead in sera of different types of gallstone patients
(2017-11-01)
A novel and greener ultrasonically assisted/modified cloud point extraction procedure for the simultaneous preconcentration of lead and cadmium in serum samples of different types of gallstone patients was developed. The ...