Buscar
Mostrando ítems 1-10 de 2608
Investigation of artifacts caused by deuterium background correction in the determination of phosphorus by electrothermal atomization using high-resolution continuum source atomic absorption spectrometry
(2008)
The artifacts created in the measurement of phosphorus at the 213.6-nm non-resonance line by electrothermal atomic absorption spectrometry using line source atomic absorption spectrometry (LS AAS) and deuterium lamp ...
Effect of different precursors on generation of reference spectra for structural molecular background correction by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry: Determination of antimony in cosmetics
(2016-12-01)
Different precursors were evaluated for the generation of reference spectra and correction of the background caused by SiO molecules in the determination of Sb in facial cosmetics by high-resolution continuum source graphite ...
Holographic p-wave superfluid in the AdS soliton background with R F-2 corrections
(Elsevier B.V., 2020-03-10)
We investigate the holographic p-wave superfluid in the background metric of the AdS soliton with RF2 corrections. Two models, namely, the Maxwell complex vector field model and Yang-Mills theory, are studied in the above ...
Internal standardization and least-squares background correction in high-resolution continuum source flame atomic absorption spectrometry to eliminate interferences on determination of Pb in phosphoric acid
(Pergamon-Elsevier B.V. Ltd, 2008-09-01)
In this work the least-squares background correction (LSBC) and internal standardization (IS) techniques were combined to eliminate spectral and transport interferences in the determination of Pb in phosphoric acid by ...
Internal standardization and least-squares background correction in high-resolution continuum source flame atomic absorption spectrometry to eliminate interferences on determination of Pb in phosphoric acid
(Pergamon-Elsevier B.V. Ltd, 2008-09-01)
In this work the least-squares background correction (LSBC) and internal standardization (IS) techniques were combined to eliminate spectral and transport interferences in the determination of Pb in phosphoric acid by ...
Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
(2007)
The literature about direct solid sample analysis of the past 10–15 years using electrothermal atomic absorption spectrometry has been reviewed. It was found that in the vast majority of publications aqueous standards were ...