Buscar
Mostrando ítems 81-90 de 1181
Influence of cone beam CT enhancement filters on diagnosis ability of longitudinal root fractures
(British Inst RadiologyLondonInglaterra, 2014)
Prevalencia de hallazgos patológicos en el seno maxilar detectados en tomografías computarizadas cone beam de los pacientes atendidos en el instituto de diagnóstico maxilofacial en el año 2017
(2018-11-30)
El objetivo de la presente investigación fue determinar la prevalencia de hallazgos patológicos en el seno maxilar detectados en las Tomografías Computarizadas Cone Beam (TCCB), de los pacientes atendidos en el Instituto ...
Accuracy of Linear Measurements in Cone Beam Computed Tomography With Different Voxel Sizes
(2012)
Objective: To evaluate the accuracy of linear measurements on dry mandible specimens using cone beam computed tomography (CBCT) images acquired with different voxel sizes. Methodology: Eight human dry mandibles were submitted ...
Assessment of simulated mandibular condyle bone lesions by cone beam computed tomography
(Sociedade Brasileira de Pesquisa Odontológica, 2010)
There are many limitations to image acquisition, using conventional radiography, of the temporomandibular joint (TMJ) region. The Computed Tomography (CT) scan is a better option, due to its higher accuracy, for purposes ...
Influence of anatomical location on CT numbers in cone beam computed tomography
(2013-04-01)
Objective: To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Study Design: Polypropylene tubes with varying ...
Influence of anatomical location on CT numbers in cone beam computed tomography
(2013-04-01)
Objective: To assess the influence of anatomical location on computed tomography (CT) numbers in mid- and full field of view (FOV) cone beam computed tomography (CBCT) scans. Study Design: Polypropylene tubes with varying ...
Correlação entre as medidas lineares em radiografias panorâmicas e tomografias computadorizadas cone beam associadas ao seio maxilar
(2013-01-01)
Objective: To correlate linear measurements between digital panoramic radiographs (DPan) and cone beam computed tomography images (CBCT) of the maxillary sinus area. Method: Seventy-one paired site exams were selected, 37 ...
Comparative study of cone beam computed tomography and intraoral periapical radiographs in diagnosis of lingual-simulated external root resorptions
(WILEY-BLACKWELLHOBOKEN, 2012)
Background: Owing to a lack of symptoms and difficult visualization in routine intraoral radiographs, diagnosis of external root resorptions can be challenging. Aim: The goal of this study was to compare two image acquisition ...
Effects of surgically assisted rapid maxillary expansion on mandibular position: a three-dimensional study
(2017-12-01)
Background: This study aimed to evaluate three-dimensional changes in mandibular position after surgically assisted rapid maxillary expansion (SARME). Methods: A retrospective study was carried out with tomographic records ...
Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors
(2013-01-01)
Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. ...