Buscar
Mostrando ítems 41-50 de 99
Analysis of the correlation between ophthalmic examination and quality of life outcomes following intracorneal ring segment implantation for keratoconus
(Conselho Brasileiro de Oftalmologia, 2011-12-01)
PURPOSE: To analyze the correlation between quantitative measurements outcomes and keratoconus patients' vision related quality of life (v-QoL) following intrastromal corneal ring segment implantation. METHODS: The NEI-RQL ...
Aplicação de filmes finos de titânio em componentes acetabulares de uhmwpe para proteção contra oxidação devido a exposição à radiação X
(Pontifícia Universidade Católica do Rio Grande do SulPorto Alegre, 2006)
The use of multi-component hip implants to replace the femur head is widespread since the 70’s. These implants consist basically of a spherical metallic head and a stem, which are generally made of the same material, mostly ...
Aplicação de filmes finos de titânio em componentes acetabulares de uhmwpe para proteção contra oxidação devido a exposição à radiação X
(Pontifícia Universidade Católica do Rio Grande do SulPorto Alegre, 2006)
The use of multi-component hip implants to replace the femur head is widespread since the 70’s. These implants consist basically of a spherical metallic head and a stem, which are generally made of the same material, mostly ...
X-ray Bragg-Surface Diffraction: A Tool to Study In-Plane Strain Anisotropy Due to Ion-Beam-Induced Epitaxial Crystallization in Fe+-Implanted Si(001)
(Amer Chemical SocWashingtonEUA, 2010)
One-Year Clinical Outcomes of a Corneal Inlay for Presbyopia
(Lippincott Williams & Wilkins, 2017)
Purpose: To report the results of a 1-year follow-up analysis of the safety and efficacy of the Flexivue Microlens corneal inlay. Methods: The Flexivue Microlens corneal inlay was implanted in the nondominant eye of patients ...
Avaliação da eficácia da facectomia com implante de lente intra-ocular na infância
(Conselho Brasileiro de Oftalmologia, 2005-12-01)
PURPOSE: To evaluate the efficacy of the use of intraocular lenses in the treatment of pediatric aphakia, according to postoperative visual acuity and refraction change. METHODS: A total of 33 eyes in 27 children were ...
Calidad geométrica en el mecanizado de superficies en polieteretercetona (PEEK) para aplicación en implantes individualizados
(2016-06-09)
Resumen: Se desea determinar los valores de velocidad de corte, avance y trayectoria adecuada para obtener valores recomendados de calidad geométrica en el mecanizado del PEEK, poli-éter-éter-cetona, para la elaboración ...