Buscar
Mostrando ítems 11-20 de 77
Seismic Response of Single-Degree-of-Freedom Systems with Structural Fuses
(2004-06-25)
Passive energy dissipation (PED) devices have been implemented to enhance structural performance by reducing seismically induced structural damage. In this article, metallic dampers are defined to be structural fuses (SF) ...
Optimized friction pendulum and precast-prestressed pile to base-isolate a Chilean masonry house
(2009)
In this study friction pendulum system (FPS) bearings and precast-prestressed pile (PPP) isolators are considered as base isolation devices for a Chilean confined masonry house. The house is numerically modeled using a ...
Full-scale shaking table test and numerical modeling of a 3000-liter legged storage tank isolated with a vertical rocking isolation system
(WILEY, 2022)
This paper presents the numerical and experimental evaluation of a vertical-rocking isolation (VRI). This evaluation is done by 1-D shaking table tests performed on a full-scale legged storage tank of 3000-liters capacity ...
Applicability of superelastic materials in seismic protection systems: A parametric study of performance in isolation of structures
(IOP Publishing, 2017-08)
The dynamic response to different seismic inputs of an isolated structure disposed on a sliding layer and connected to the ground with a superelastic NiTi device was analyzed. The device allows wires of NiTi to be mechanically ...
Performance of bridges with seismic isolation bearings during the Maule earthquake, Chile
(Elsevier, 2013)
On February 27, 2010 an earthquake of magnitude Mw=8.8, with epicenter in Cobquecura, Maule region, hit the central part of Chile. After the earthquake, a tsunami occurred that caused heavy casualties and damage to buildings ...
Análisis sísmico estructural comparativo entre edificios empotrados en su base y con aisladores de base tipo elastoméricos y friccionantes, para las microzonas Lacustre y Piedemonte de BogotáComparative structural seismic análisis between fixed base buildings and with isolated at their base elastomeric and friction buildings types for microzones Lacustre and Piedemonte in Bogotá
(Maestría en Ingeniería CivilFacultad de IngenieríaUniversidad Militar Nueva Granada, 2023)
Diseño y análisis de edificaciones con aisladores de base tipo FPT
(2018)
Designing structures that have the capacity to mitigate the effects of earthquakes in areas of high seismic hazard, such as Ecuador, is required to avoid economic losses and human lives, in this sense, several seismic ...
Evaluación de la respuesta sísmica de un puente vehicular con incorporación de aislamiento sísmico de péndulo de fricción en la base de las columnasEvaluation of he seismic response of a vehicular bridge with the incorporation of seismic isolation of friction pendulum at the base of the columns
(Maestría en Ingeniería CivilFacultad de IngenieríaUniversidad Militar Nueva Granada, 2023)