Buscar
Mostrando ítems 11-20 de 156
Mechanical behavior of different micro conical abutments in fixed prosthesis
(2018-01-01)
Purpose: To evaluate the biomechanical behavior between two different micro conical abutments: two-piece and one-piece abutments. Materials and Methods: Four groups were divided according to the prosthetic connection ...
Fracture Resistance of the Implant-Abutment Connection in Implants with Internal Hex and Internal Conical Connections Under Oblique Compressive Loading: An In Vitro Study
(QUINTESSENCE PUBLISHING CO INC, 2009)
The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty ...
Evaluation of implants with different macrostructures in type I Bone-Pre-Clinical study in rabbits
(2020-04-01)
The objective of this study was to assess the primary stability and the osseointegration process in implants with different macrostructures (Cylindrical vs. Hybrid Conical) in rabbit tibiae. Twenty-four (24) rabbits were ...
Distribuição de tensões em overdentures suportadas por implantes cônicos e cilíndricos: análise por elemento finito tridimensional
(Pontifícia Universidade Católica do Rio Grande do SulPorto Alegre, 2008)
This study using 3D-finite element analysis compared the stress distribution generated by a static load on implant-supported overdenture as a function of implant geometry (cylindrical versus conical shape). Tridimensional ...
Distribuição de tensões em overdentures suportadas por implantes cônicos e cilíndricos: análise por elemento finito tridimensional
(Pontifícia Universidade Católica do Rio Grande do SulPorto Alegre, 2008)
This study using 3D-finite element analysis compared the stress distribution generated by a static load on implant-supported overdenture as a function of implant geometry (cylindrical versus conical shape). Tridimensional ...
Influence of implants with different sizes and configurations installed immediately into extraction sockets on peri-implant hard and soft tissues: an experimental study in dogs
(Wiley-Blackwell, 2012-04-01)
Aim: To study the influence on the healing of soft and hard peri-implant tissues when implants of different sizes and configurations were installed into sockets immediately after tooth extraction.Material and methods: ...
Influence of implants with different sizes and configurations installed immediately into extraction sockets on peri-implant hard and soft tissues: an experimental study in dogs
(Wiley-Blackwell, 2012-04-01)
Aim: To study the influence on the healing of soft and hard peri-implant tissues when implants of different sizes and configurations were installed into sockets immediately after tooth extraction.Material and methods: ...
Cavidade anoftálmica adquirida: avaliação da influência dos implantes orbitários cônicos ou esféricos sobre as versões do olhar e sobre o posicionamento do supercílio e das pálpebras superiores e inferiores; e percepção dos oftalmologistas oculoplásticos com relação ao manejo do portador de cavidade anoftálmica
(Universidade Estadual Paulista (Unesp), 2021-08-25)
Existem vários aspectos da cavidade anoftálmica a serem melhor estudados. Os movimentos do implante orbitário e da prótese ocular externa (POE) não são semelhantes aos do olho normal e este é um ponto muito importante a ...
Distribuição de tensões em mini-implantes ortodônticosStress distribution in orthodontic mini-implants
(Rede Latino-Americana de Materiais, 2010)
O objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico ...
Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães
(Universidade Estadual Paulista (UNESP), 2014)