Buscar
Mostrando ítems 11-20 de 1551
Computer-Assisted Numerical Analysis for Oxygen and Carbon Dioxide Mass Transfer in Blood Oxygenators
(WILEY-BLACKWELL, 2011)
A two-dimensional numeric simulator is developed to predict the nonlinear, convective-reactive, oxygen mass exchange in a cross-flow hollow fiber blood oxygenator. The numeric simulator also calculates the carbon dioxide ...
Concordance analysis between dosed serum bicarbonate and that calculated by gas analysis in chronic renal patients
(Sociedade Brasileira de Nefrologia, 2020-05-11)
Clinical and blood gas analysis of calves conceived by artificial insemination, in vitro fertilization and animal cloning1
(2019-01-01)
In order for successful extra-uterine adaptation to occur, it is necessary for the neonate to be able to establish its respiratory functions effectively, guaranteeing efficient oxygenation and good vitality. Respiratory ...
Evaluation of blood compatibility of plasma deposited heparin-like films and SF6 plasma treated surfaces
(2010-01-01)
In devices used in open-heart surgery and dialysis, blood must be continuously processed using extracorporeal circuits composed of peristaltic pumps and active components such as specifc flters and oxygenators. Several ...
Evaluation of blood compatibility of plasma deposited heparin-like films and SF6 plasma treated surfaces
(2010-01-01)
In devices used in open-heart surgery and dialysis, blood must be continuously processed using extracorporeal circuits composed of peristaltic pumps and active components such as specifc flters and oxygenators. Several ...
Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheep
(Amer Veterinary Medical Assoc, 2010-05-01)
Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer ...
Evaluation of a portable clinical analyzer for the determination of blood gas partial pressures, electrolyte concentrations, and hematocrit in venous blood samples collected from cattle, horses, and sheep
(Amer Veterinary Medical Assoc, 2010-05-01)
Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer ...
Effect of remifentanil hydrochloride administered via constant rate infusion on the minimum alveolar concentration of isoflurane in cats
(2009-05-01)
Objective - To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals - 6 healthy ...
Effect of remifentanil hydrochloride administered via constant rate infusion on the minimum alveolar concentration of isoflurane in cats
(2009-05-01)
Objective - To evaluate the effects of increasing doses of remifentanil hydrochloride administered via constant rate infusion (CRI) on the minimum alveolar concentration (MAC) of isoflurane in cats. Animals - 6 healthy ...
Efeitos da corticoterapia materna nos valores hemogasométricos de cordeiros nascidos a termo e prematuros
(2017-05-01)
The aim of the study was to evaluate blood gas parameters of full-term and premature lambs from birth to 48 hours of life. Four experimental groups were formed: NDG (normal delivery group - lambs vaginally delivered, n=15, ...