Buscar
Mostrando ítems 11-20 de 175
Determination of aluminum in highly concentrated iron samples: Study of interferences using high-resolution continuum source atomic absorption spectrometry
(2007)
High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) has been used to investigate spectral and non-spectral interferences found with a conventional line source atomic absorption spectrometer in the ...
Investigation of artifacts caused by deuterium background correction in the determination of phosphorus by electrothermal atomization using high-resolution continuum source atomic absorption spectrometry
(2008)
The artifacts created in the measurement of phosphorus at the 213.6-nm non-resonance line by electrothermal atomic absorption spectrometry using line source atomic absorption spectrometry (LS AAS) and deuterium lamp ...
Optimization of fluorine determination via the molecular absorption of gallium mono-fluoride in a graphite furnace using a high-resolution continuum source spectrometer
(2010)
The determination of fluorine using the molecular absorption of gallium mono-fluoride (GaF) at the 211.248 nm rotational line has been optimized using a commercially available high-resolution continuum source atomic ...
Detection of the origin of Brazilian wines based on the determination of only four elements using high-resolution continuum source flame AAS
(Talanta, 2013)
A method has been developed to determine 10 elements in Brazilian red wines using high-resolution continuum source flame atomic absorption spectrometry, a technique that allows the fast sequential determination of an ...
Detection of the origin of Brazilian wines based on the determination of only four elements using high-resolution continuum source flame AAS
(2013)
A method has been developed to determine 10 elements in Brazilian red wines using high-resolution continuum source flame atomic absorption spectrometry, a technique that allows the fast sequential determination of an ...
Unusual calibration curves observed for iron using high-resolution continuum source graphite furnace atomic absorption spectrometry
(Elsevier, 2010)
The simultaneous determination of cadmium and iron in plant and soil samples has been investigated using
high-resolution continuum source graphite furnace atomic absorption spectrometry. The primary cadmium
resonance ...
Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling
(Elsevier B.V., 2012-10-15)
A procedure is proposed for Pb determination in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) using direct solid sampling. Among Pd(NO3)(2), Pd/Mg(NO3)(2). ...
Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling
(Elsevier B.V., 2012-10-15)
A procedure is proposed for Pb determination in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) using direct solid sampling. Among Pd(NO3)(2), Pd/Mg(NO3)(2). ...
Determination of chlorine in cement via CaCl molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry with direct solid sample analysis
(2017-05-01)
The use of a new molecule the calcium mono-chloride (CaCl) with absorption band head at 621.145 nm was evaluated in the development of a method for Cl determination in cement by high-resolution continuum source graphite ...
Internal standardization and least-squares background correction in high-resolution continuum source flame atomic absorption spectrometry to eliminate interferences on determination of Pb in phosphoric acid
(Pergamon-Elsevier B.V. Ltd, 2008-09-01)
In this work the least-squares background correction (LSBC) and internal standardization (IS) techniques were combined to eliminate spectral and transport interferences in the determination of Pb in phosphoric acid by ...