Buscar
Mostrando ítems 1-10 de 392
Resonant (P+RES) controller applied to voltage source inverter with minimum DC link capacitor
(2011-12-28)
Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the ...
Resonant (P+RES) controller applied to voltage source inverter with minimum DC link capacitor
(2011-12-28)
Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the ...
Dynamic DC-Link Voltage Control of Back to Back Modular Multilevel Converter for Drive Applications
(IEEE, 2019)
In this work a dynamic control of the dc-link voltage in a hybrid Back-to-Back (BtB) Modular Multilevel Converter for medium-voltage drive applications is presented. The proposed control scheme relates the speed of the ...
Voltage-source active power filter based on multilevel converter and ultracapacitor DC link
(2006)
A new topology for active power filters (APF) using an 81-level converter is analyzed. Each phase of the converter is composed of four three-state converters, all of them connected to the same capacitor dc link voltage and ...
RESONANT (P plus RES) CONTROLLER APPLIED TO VOLTAGE SOURCE INVERTER WITH MINIMUM DC LINK CAPACITOR
(Ieee, 2011-01-01)
Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the ...
Voltage source active power filter, based on multi-stage converter and ultracapacitor dc-link
(IEEE, 2003)
A multi-stage inverter using three-state converters is being analyzed for active filter and static var compensator applications. Each phase of the converter is composed of four three-state converters, all of them connected ...
High-Frequency Link: A Solution for Using Only One DC Source in Asymmetric Cascaded Multilevel Inverters
(IEEE, 2011)
Multilevel inverters are in state-of-the-art power conversion systems due to their improved voltage and current waveforms. Cascaded H-bridge (CHB) multilevel inverters have been considered as an alternative in the ...
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter
(2011-12-28)
The Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral ...
3-D Space Vector PWM implementation for Four-Leg Voltage Source Inverter
(2011-12-28)
The Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral ...