dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorOliveira, A. P.
dc.creatorNeto, JAG
dc.creatorNobrega, J. A.
dc.creatorCorreia, PRM
dc.creatorOliveira, P. V.
dc.date2014-05-20T15:22:50Z
dc.date2016-10-25T17:56:37Z
dc.date2014-05-20T15:22:50Z
dc.date2016-10-25T17:56:37Z
dc.date2005-11-01
dc.date.accessioned2017-04-05T23:38:49Z
dc.date.available2017-04-05T23:38:49Z
dc.identifierFood Chemistry. Oxford: Elsevier B.V., v. 93, n. 2, p. 355-360, 2005.
dc.identifier0308-8146
dc.identifierhttp://hdl.handle.net/11449/33744
dc.identifierhttp://acervodigital.unesp.br/handle/11449/33744
dc.identifier10.1016/j.foodchem.2004.11.024
dc.identifierWOS:000229707800023
dc.identifierhttp://dx.doi.org/10.1016/j.foodchem.2004.11.024
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/877801
dc.descriptionA method has been developed for the direct determination of Se in nutritionally relevant foods by graphite furnace atomic absorption spectrometry. Tungsten/rhodium carbide coating on the integrated platform of a transversely heated graphite atomizer or W coating with co-injection of Pd(NO3)(2) were used as a permanent modifiers. Samples and reference solutions were spiked with 500 mu g L-1 As and absorbance variations due to changes in experimental conditions were minimized. For 20 mu L aqueous analytical solutions delivered into the graphite tube, analytical curves in the 5.0-40 mu g L-1 with good linear correlation were established. Pyrolysis and atomization temperatures were evaluated using pyrolysis and atomization curves, respectively. The optimized heating program (temperature, ramp time, hold time) of the graphite tube of the Perkin-Elmer SIMAA 6000 atomic absorption spectrometer was: dry steps (110 degrees C, 5 s, 10 s; 130 degrees C, 15 s, 15 s); air-assisted pyrolysis step (600 degrees C, 20 s, 40 s; 20 degrees C, 1 s, 40 s); pyrolysis step (1300 degrees C, 10 s, 20 s); atomization step (2100 degrees C, 0 s, 4 s); clean step (2550 degrees C, 1 s, 5 s). The method was applied for Se determination in coconut water, coconut milk, soybean milk, cow milk, tomato juice, mango juice, grape juice and drinking water samples and four standard reference materials and results were in agreement at 95% confidence level. The lifetime of the tube was 500 firings and the relative standard deviations of measurements of typical samples containing 25 mu gL(-1) Se were 3.0% and 6.0% (n = 12) with and without internal standardization, respectively. The limits of detection were in the 0.35 mu g L-1-0.7 mu g Se L-1 range. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 98-109% range. (c) 2004 Elsevier Ltd. All rights reserved.
dc.languageeng
dc.publisherElsevier B.V.
dc.relationFood Chemistry
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectselenium
dc.subjectnutritionally relevant food
dc.subjectgraphite furnace atomic absorption spectrometry
dc.subjectinternal standardization
dc.subjectsimultaneous determination
dc.titleDetermination of selenium in nutritionally relevant foods by graphite furnace atomic absorption spectrometry using arsenic as internal standard
dc.typeOtro


Este ítem pertenece a la siguiente institución