Problems related to the employment of thin uranium films as neutron dosimeters
Fecha
1995-12-01Registro en:
Radiation Measurements, v. 25, n. 1-4, p. 459-460, 1995.
1350-4487
10.1016/1350-4487(95)00162-8
WOS:A1995RE48000114
2-s2.0-0010092648
Autor
CNR
Universidade Estadual de Campinas (UNICAMP)
Instituto de Pesquisas Energéticas e Nucleares (IPEN)
Universidade Estadual Paulista (Unesp)
Institución
Resumen
Thin uranium films built on muscovite mica basis and obsidian samples having known ages were irradiated with thermal neutrons at the IPEN/CNEN reactor, São Paulo. Comparing thin film performance with the obsidian one, it was observed that the latter feel a greater neutron fluence. Nominal fluences at the used facility are in agreement with the results obtained analysing the obsidian samples. A probable hypothesis to explain this disagreement, namely, the uranium loss from the thin films, was ruled out. © 1995.