dc.creatorBoiero, Carolina
dc.creatorAllemandi, Daniel Alberto
dc.creatorLonghi, Marcela Raquel
dc.creatorLlabot, Juan Manuel
dc.date.accessioned2018-10-24T16:46:58Z
dc.date.accessioned2018-11-06T15:31:23Z
dc.date.available2018-10-24T16:46:58Z
dc.date.available2018-11-06T15:31:23Z
dc.date.created2018-10-24T16:46:58Z
dc.date.issued2015-07
dc.identifierBoiero, Carolina; Allemandi, Daniel Alberto; Longhi, Marcela Raquel; Llabot, Juan Manuel; RP-HPLC method development for the simultaneous determination of timolol maleate and human serum albumin in albumin nanoparticles; Elsevier Science; Journal of Pharmaceutical and Biomedical Analysis; 111; 7-2015; 186-189
dc.identifier0731-7085
dc.identifierhttp://hdl.handle.net/11336/62987
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1898076
dc.description.abstractAn isocratic high-performance liquid chromatographic method was developed and validated for the simultaneous determination of human serum albumin (HSA) and timolol in albumin nanoparticles. This method involved a reversed-phase-C18 column thermostated at 25. °C, UV detection at 276. nm, flow rate of 1.0. ml/min and a mobile phase compounded by 0.05% (v/v) trifluoroacetic acid in water/0.05% (v/v) trifluoroacetic acid in an acetonitrile (40:60, v/v) solution. The elution times for albumin and timolol were 1.84 ± 0.05 min and 2.67 ± 0.04 min, respectively. Calibration curves were linear from 0.2 to 100 mg/ml for HSA and 0.01 to 1 mg/ml for timolol. Limits of quantification were 0.2 mg/ml for HSA and 0.01 mg/ml for timolol. The values of accuracy and precision of intra- and inter-day variation studies were within acceptable limits, according to the US Food and Drug Administration Guidance for Industry. The described method has proved to be useful to give accurate measurements of human serum albumin and timolol from albumin nanoparticles to determine the percentage of encapsulation and the process yield.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.jpba.2015.03.031
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0731708515002083
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHPLC
dc.subjectHUMAN SERUM ALBUMIN
dc.subjectPROTEIN NANOPARTICLES
dc.subjectTIMOLOL MALEATE
dc.subjectVALIDATION
dc.titleRP-HPLC method development for the simultaneous determination of timolol maleate and human serum albumin in albumin nanoparticles
dc.typeArtículos de revistas
dc.typeArtículos de revistas
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución