dc.creatorMoraes, Marlene Silva de
dc.creatorLima, Jose Renato Baptista de
dc.creatorMoraes Júnior, Deovaldo de
dc.creatorLia, Luis Renato Bastos
dc.creatorPizzo, Sandro Megale
dc.date.accessioned2012-03-26T02:11:55Z
dc.date.accessioned2018-07-04T13:54:20Z
dc.date.available2012-03-26T02:11:55Z
dc.date.available2018-07-04T13:54:20Z
dc.date.created2012-03-26T02:11:55Z
dc.date.issued2008
dc.identifierREM: Revista Escola de Minas, Ouro Preto, v. 61, n. 1, p. 25-28, jan./mar. 2008
dc.identifier0370-4467
dc.identifierhttp://producao.usp.br/handle/BDPI/4472
dc.identifier10.1590/S0370-44672008000100005
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0370-44672008000100005
dc.identifierhttp://www.scielo.br/pdf/rem/v61n1/a05v61n1.pdf
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1603271
dc.description.abstractO presente texto descreve um equipamento na escala-piloto e um método simples para comparar a eficiência de distribuidores de líquido. A técnica consiste basicamente em analisar a massa do líquido coletado em 21 tubos verticais de 52mm de diâmetro interno e 800 mm de comprimento dispostos em arranjo quadrático colocados abaixo do distribuidor. Uma manta acrílica que não dispersa o líquido com 50 mm de espessura foi fixada entre o distribuidor e o banco de tubos para evitar respingos. Como exemplo de aplicação foram realizados ensaios com nove distribuidores do tipo espinha de peixe de 4 tubos paralelos cada, para uma coluna com 400 mm de diâmetro. Variaram-se o número (n) de furos (95, 127 e 159 furos/m²), o diâmetro (d) dos furos (2, 3 e 4 mm) e as vazões (q) de (1,2; 1,4 e 1,6m³/h). A melhor eficiência de espalhamento pelo menor desvio-padrão foi obtida com n de 159, d de 2 e q de 1,4 indicando as limitações de regras práticas de projeto. A pressão (p), na entrada do distribuidor, para essa condição, foi de apenas 51000 Pa (0,51 kgf/cm²) e a velocidade média (v) em cada orifício foi de 6,3 m/s.
dc.description.abstractThis paper describes a device developed on the pilot scale and a simple approach to compare liquid distributor efficiencies. The technique consists basically of analyzing the mass of the liquid collected in 21 vertical pipes measuring 52 mm in internal diameter and 800 mm in length placed in a quadratic arrangement and positioned below the distributor. A 50 mm thick acrylic blanket that does not disperse liquids was placed between the distributor and the pipe bank to avoid splashes. Assays were carried out with ladder-type distributors equipped with 4 parallel pipes each for a column measuring 400 mm in diameter as an example of the application. The number (n) of orifices (95, 127, and 159 orifices/m²), orifice diameter (d) (2, 3, and 4 mm) and the flowrate (q) (1.2; 1.4; and 1.6 m3/h) were varied. The best spread efficiency, which presented the lowest standard deviation, was achieved with 159 orifices, 2 mm and 1.4 m³/h. The pressure (p) at the distributor's inlet for this condition was only 51000 Pa (0.51 kgf/cm²), while the average velocity (v) was 6.3 m/s in each orifice. These results show some limitations of the practical rules used in distributor designs.
dc.languagepor
dc.publisherEscola de Minas
dc.relationRem: Revista Escola de Minas
dc.rightsCopyright Escola de Minas
dc.rightsopenAccess
dc.subjectDistribuidores
dc.subjectEscala-piloto
dc.subjectLavagem de gases
dc.subjectDespoeiramento
dc.subjectTratamento de água
dc.subjectAspersão de líquidos
dc.subjectAdsorção
dc.subjectAbsorção
dc.subjectDestilação
dc.subjectLiquid aspersion
dc.subjectDistributors
dc.subjectLiquid distributor
dc.subjectPilot scale
dc.subjectGas washing
dc.subjectAdsorption
dc.subjectAbsorption
dc.subjectDistillation
dc.titleExperimento para quantificar a eficiência de aspersão de líquidos: aplicação em distribuidores espinha de peixe
dc.typeArtículos de revistas