Development and comparison of analytical techniques, liquid chromatography to high-efficiency and capillary electrophoresis, in the determination of artificial coloring

dc.creatorPrado, Marcelo Alexandre, 1966-
dc.date2003
dc.date2003-09-06T00:00:00Z
dc.date2017-03-27T23:25:39Z
dc.date2017-07-07T19:22:07Z
dc.date2017-03-27T23:25:39Z
dc.date2017-07-07T19:22:07Z
dc.date.accessioned2018-03-29T03:16:11Z
dc.date.available2018-03-29T03:16:11Z
dc.identifier(Broch.)
dc.identifierPRADO, Marcelo Alexandre. Desenvolvimento e comparação de tecnicas analiticas, cromatografia a liquido de alta eficiencia e eletroforese capilar, na determinação de corantes artificiais. 2003. 130 p. Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos, Campinas, SP. Disponível em: <http://www.bibliotecadigital.unicamp.br/document/?code=vtls000295918>. Acesso em: 27 mar. 2017.
dc.identifierhttp://repositorio.unicamp.br/jspui/handle/REPOSIP/254299
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/1328620
dc.descriptionOrientador: Helena Teixeira Godoy
dc.descriptionTese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos
dc.descriptionResumo: O uso de corantes artificiais pelas indústrias de alimentos em todo o mundo é bastante difundido, isto porque os corantes permitem suplementar ou repor a coloração perdida durante o processamento e ou estocagem, e assim garantir a aceitabilidade do produto frente ao consumidor, sendo utilizados ainda como um importante instrumento para garantir a uniformidade dos produtos em linhas de produção de larga escala. Do ponto de vista da saúde pública, existem diferentes opiniões quanto à inocuidade dos diversos corantes artificiais utilizados em alimentos. Muitos estudos mostram que esses aditivos podem causar uma série de males à saúde da população quando consumidos de forma incorreta, seja por abusos da indústria ou exagero no consumo. O fato é que, técnicas analíticas para a determinação desses corantes devem ser desenvolvidas, e principalmente validadas, para garantir a segurança alimentar dos produtos que ingerimos. No presente trabalho foram desenvolvidos e validados dois métodos para a determinação de corantes artificiais em bebidas alcoólicas, utilizando duas diferentes técnicas, a cromatografia a líquido de alta eficiência (CLAE) e a eletroforese capilar (EC). Os métodos foram desenvolvidos para a separação simultânea dos onze corantes artificiais permitidos para uso em alimentos no Brasil. No método por CLAE, para a separação dos corantes, utilizou-se coluna de fase reversa e eluição por gradiente, com fase móvel composta por água/metanol. Na EC a separação ocorreu utilizando um capilar de sílica, com 73 cm de comprimento efetivo, preenchido com uma solução tampão composta por fosfato (10mmol/L) e dodecil sulfato de sódio (l0mmol/L), a pH 11, com aplicação de voltagem de 25 kV. Nos dois métodos, a detecção dos corantes foi feita na região do visível e a quantificação através de curvas de calibração externa. Os limites de detecção obtidos ficaram na faixa de 0,1 a 0,4 µ tg/mL e 0,4 a 2,5 µ tg/mL, enquanto os limites de quantificação foram de 0,2 a 1,3 µ tg/mL e 1,3 a 7,1 µ tg/mL para a CLAE e EC, respectivamente. As taxas de recuperação, em dois níveis de concentração, para todos os corantes foram de 95,2 a 103,2% para a CLAE, e de 92,6 a 104,0% para a EC. Os valores de repetibilidade calculado para padrões e amostras demonstraram a boa precisão para os dois métodos desenvolvidos. As metodologias propostas e validadas foram aplicadas em 45 amostras de bebidas alcoólicas de diferentes fabricantes brasileiros, sendo: 6 aguardentes aromatizadas, 9 coolers, 7 aperitivos, 3 coquetéis, 8 licores e 12 vinhos tinto. Não houve diferença significativa entre os dados obtidos pelos dois métodos. Em todas as amostras analisadas, os teores de corantes artificiais encontrados estavam em conformidade com a legislação brasileira
dc.descriptionAbstract: The use of synthetic dyes for the food industries in the whole world is sufficiently spread out, it is because the colors allow to supplemental or to replace the lost coloration during the processing and or storage, and thus to guarantee the acceptability of the product front to the consumer, being used still as an important instrument to guarantee the uniformity of the products in the production. Of the point of view of the public health, there are different opinions about the safety of the different synthetic dyes used in foods. Much of the studies show that these additives can be dangerous for the health of the population when consumed inadequately, either for abuses of the industry or exaggerate in the consumption. The fact is that, analytical methods for the determination of these colors must be developed, and mainly validated, to guarantee the alimentary security of the products that we ingest. In the present work they had been developed and validated two methods for synthetic dyes determination in alcoholic beverages, using two different techniques, the high performance liquid chromatography (HPLC) and capillary eletrophoresis (CE). The methods had been developed for the simultaneous separation of the eleven synthetic dyes allowed for use in foods in Brazil. In the method for HPLC, for the separation of the synthetic dyes, a reverse phase column was used with gradient elution system composed by water/methanol. In the EC method the separation occurred using a silica capillary with 73 cm of effective length, filled with buffer phosphate solution (l0mmol/L) with sulpfate dodecyl sodium (SDS) (10mmol/L), at pH 11, with application 25kV of voltage. The detection and quantification were done made in same manner for the two methods, using absorption in the visible region and external standardization, respectively. The detection limits were 0.1 to 0.4 µ g/rnL and 0.4 to 2.5 µ g/rnL, while quantification limits were 0.2 to 1.3 µ g/rnL and 1.3 to 7.1 µ g/rnL for HPLC and CE, respectively. Recovery percentage at two levels of concentration for all the synthetic dyes were of the order of 95.2 to 103.2% for HPLC, and of92.6 to 104.0% for CE. The values of repeatability calculated for standards and samples demonstrated the precision of the two methods. The proposed and validated methods were used to analyses 45 alcoholic beverage samples of different Brazilian manufacturers, being: 6 perfumed spirits, 9 coolers, 7 bitters, 3 cocktails, 8 liquors and 12 red wines. The data obtained were the two methods did not present significant difference. It was observed that the limits permitted by Brazilian Legislation for the use of these synthetic dyes were respected in the analyzed samples
dc.descriptionDoutorado
dc.descriptionMestre em Ciencia de Alimentos
dc.format130 p.
dc.formatapplication/pdf
dc.languagePortuguês
dc.publisher[s.n.]
dc.subjectCorantes
dc.subjectCromatografia líquida de alta eficiência
dc.subjectEletroforese capilar
dc.subjectBebidas
dc.subjectAlimentos - Análise
dc.subjectDyes
dc.subjectHigh performance liquid chromatography
dc.subjectCapillary electrophoresis
dc.subjectSpirits
dc.subjectFood - Review
dc.titleDesenvolvimento e comparação de tecnicas analiticas, cromatografia a liquido de alta eficiencia e eletroforese capilar, na determinação de corantes artificiais
dc.titleDevelopment and comparison of analytical techniques, liquid chromatography to high-efficiency and capillary electrophoresis, in the determination of artificial coloring
dc.typeTesis


Este ítem pertenece a la siguiente institución